L051 Submersible Pressure Transmitter
Model :
L051
Features : Suitable for water level measurement. Submersible type. Cost effective.
Sensor type : Piezoresistive diaphragm
Measuring range : 0 ... 10 bar
Output : 4 ... 20 mA
Accuracy : ±0.5% F.S.
IP rating : IP68
Sensor type : Piezoresistive diaphragm
Measuring range : 0 ... 10 bar
Output : 4 ... 20 mA
Accuracy : ±0.5% F.S.
IP rating : IP68
-
Features● Housing SS316 outer, diameter 27 Ø
● Compact and rugged design and easy to install
● With reasonable price, high accuracy and good stability in a long-run
● Cable material: PVC or PTFE -
ApplicationsThis submersible pressure transmitter is easy to apply in open container and rivers / Plunge the transmitter into the bottom of rivers and you can get level signal of lower limit and upper limit / Drinking water equipment / Pit sinking / Waste water plant / Big container and barrel / Flow current ( rivers and lakes )
-
Download
-
Specification
Input
Sensor type
Piezoresistive diaphragm
Input type
Level
Measuring range
0 ... 10 bar
Cable overload range
Pressure range
0.5
1
2
5
10
Overload range
2.5
3
4
7
15
Output
Output
4 … 20 mA
Signal connection
2-wire
Linear accuracy
±0.5% of F.S
Load resistance
[Ohm] ≦(Operating voltage 10V)/ 0.02A-0.15Ω x cable length(M)
Output calibration(ZERO & SPAN) adjustment range
±10% of Zero-point and full-scale
Response time
≦5 ms
Environment
Measuring medium
Liquid
Operating temperature
0 ... 50°C
Operating humidity
100%RH
Storage temperature
-25 ... +60℃
Zero-point error
±0.2% F.S. / 10 K
Electrical
Power supply
DC 10 ... 30 V
Current consumption
<21 mA
Overvoltage protection
≦DC 33 V
Electrical connection
Specific cable
Installation
Installation
Submersible
Certification
Certification
CE
Protection
IP rating
IP68
Electrical protection
■ Over-voltage
■ Reverse polarity
■ Short-circuitMaterial
Housing
SUS 316
Wetted part
SUS 316
Cable
PVC / PTFE
Weight
350 g
Note : Design and specifications are subject to change without notice.
Note : If the product has RS-485 function, to avoid damaging product, please make sure the product and the device which connect with RS-485 are on common ground.