• FDM06-P Average Flow Thermal Mass Transmitter
  • FDM06-P Average Flow Thermal Mass Transmitter
  • FDM06-P Average Flow Thermal Mass Transmitter

FDM06-P Average Flow Thermal Mass Transmitter

Model : FDM06-P
Sensor type : Hot-wire sensor
Turndown ratio : 100 : 1
Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
Accuracy : 0.5 ... 60 m/s:±(1.5% of mv + 0.8 m/s)
IP rating : IP65
  • Features
    ● High Sensitivity, Low Pressure Loss, Detects Minute Airflow Changes
    ● No Compensation Needed, Direct Flow Output
    ● Sizes 1″~40″, Easy Installation
    ● ±1.5% F.S. Accuracy, 16 bar Pressure Resistance
    ● Analog, Relay, RS-485 Outputs
    ● Suitable for various types of gases (N2, Ar, CO2, etc.)
  • Applications
    Compressed Air System Management / Optimization of Air Compressors & Pneumatic Equipment Efficiency / Air Dryer Flow Control / Process Gas Consumption Monitoring (N2, Ar, CO2, etc.) / Pipeline Leak Detection & Alerts / HVAC Duct Monitoring / Smart Manufacturing Energy Management / Cleanroom Airflow Monitoring / Biotech & Pharmaceutical Gas Supply Stability Monitoring / Food Processing Gas Filling & Packaging Monitoring
  • Download
  • Specification

    Input

    Sensor type
    Hot-wire sensor
    Turndown ratio
    100 : 1
    Measuring range
    0 ... 60 m/s

    Output

    Output signal
    4 ... 20 mA / 0 ... 10 V / Relay / RS-485
    Signal connection
    3-wire
    Warm-up time
    60 sec
    Response time
    t90≦6 sec
    Load resistance
    Current output : ≦500 Ω
    Voltage output : ≧10 KΩ

    Communication

    Communication methods & protocol
    RS-485 Modbus RTU
    RS-485 baud rate
    9600、19200、38400、57600、115200 bps

    Accuracy

    Accuracy
    0.5 ... 60 m/s : ±(1.5% of mv + 0.8 m/s)
    Temp. influence
    0.2% / °C
    Uncertainty of factory calibration
    ±1%
    *The measurement range is defined at the standard condition(1013 mbar, 20°C).
    *mv = measured value

    Environmental

    Medium
    Non-corrosion gas
    Operating Temp.
    0 ... 50°C / 0 ... 180°C (High Temp. type)
    Operating Humidity
    20 ... 90%RH(Non-condensing)
    Storage Temp.
    -20 ... +60°C
    Operating pressure
    16 bar

    Electrical

    Power supply
    DC 24 V ±10%
    Current consumption
    24 V : 110 mA
    Relay capacity
    Max current : 6 A
    Max voltage : DC 24 V (DC 36 V Max)
    Electrical connection
    M12 8P connector

    Installation

    Installation
    PT 3/4″ movable thread, PT 1/2″ movable thread

    Display

    Display readout
    0 ... 99999999 (Cumulative flow : 8-digit)
    0 ... 99999 (Instantaneous flow : 5-digit)
    Decimal point
    Button
    Sampling time
    1 cycle/sec
    Flow unit
    m/s, ft/s, L/min, m³/min, m³/h, mL, L
    m³, ft³, inch³, gal, uk gal
    Response time adjustment range
    0.5 ... 300 sec

    Certification

    Certification
    CE

    Protection

    IP rating
    IP65(Housing)
    Electrical protection
    ■ Reverse polarity ■ Over-voltage

    Material

    Housing
    Aluminum alloy / Plastic
    Probe
    SUS316

Note : Design and specifications are subject to change without notice.
Note : If the product has RS-485 function, to avoid damaging product, please make sure the product and the device which connect with RS-485 are on common ground.