• eYc THS88MAX Industrial High Pressure Dew Point Transmitter

eYc THS88MAX Industrial High Pressure Dew Point Transmitter

Max. scaling range : Dew point:-100 ... +60 dp°C
Linear accuracy : ±1 dp°C (at -20 ... +20 dp°C)
±1.5 dp°C(at -40 ... +20 dp°C)
±2 dp°C (at -60 dp°C)
Reference (at -100 ... -60 dp°C)
Power supply : DC 24 V±15%
Installation : 1/2’’PT, 1/2’’G, and 5/8’’UNF
IP rating : IP65(Probe:IP20)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

-Features
Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output
Reduce insensitivity temperature zone, quickly response
Hysteresis compensation, resistance to moisture, extreme high and low humidity impact
EMC anti-interference, anti-condensation, low-temperature influence, long-term stability
Three thread (1/2″PT, 1/2″G, and 5/8″UNF) mode can be selected

More potential product articles, welcome to visit the link below
eYc-Success-StoryeYc-FAQ

Input
Input type : Capacitive humidity sensor & Pt100
Operating range of dew point : -100 ... +60 dp°C

Output
Max. scaling range : Dew point:-100 ... +60 dp°C
Dew point switch to another physical quantity range : 
                                                                                    Frost point:-60 ... 0 fp°C
                                                                                    Absolute humid.(Volume)0 ... 50000 ppm/v
                                                                                    Absolute humid.(Weight)0 ... 50000 ppm/w
Output signal : Standard RS-485 & 1 analog output 4 ... 20 mA / 0 ... 10 V
Signal connection : 3-wire
Linear accuracy : ±1 dp°C (at -20 ... +20 dp°C)
                             ±1.5 dp°C(at -40 ... +20 dp°C)
                             ±2 dp°C (at -60 dp°C)
                             Reference (at -100 ... -60 dp°C)
Load resistance : Current output:Max.500 Ω;Voltage output:Min.10 KΩ

Electrical
Power supply : DC 24 V±15%
Current consumption : DC 24 V, 50 mA
Electrical connection : M12 connector

Environment
Output calibration (ZERO & SPAN) adjustment range : Software 
Response time t90(Temp. at+25°C) : <20 sec
Medium : Air
Operating Temp. for housing : -40 ... +60°C
Operating Humid. for housing : 0 ... 95%RH (Non-condensing)
Operating Temp. for probe : -40 ... +60°C
Storage temperature : -25 ... +60°C
Pressure resistance : 16 bar

Installation
Installation : 1/2″PT, 1/2″G, and 5/8″UNF

Protection
IP rating : IP65(Probe:IP20)
Electrical protection : ■ Polarity protection ■ Over-voltage ■ Short-circuit

Material
Housing : S.S.(SUS304)
Probe : S.S.(SUS304);SUS sintered filter(SUS316)
Weight : 168 g

*Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect.
Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.


Compressed air system / Air separation equipment / Freezer / Adsorption machine / Plastic dryer / Industrial drying process / Paper / Chemical process monitoring