GS43/44 CO2 Transmitter(Indoor / Duct Type)
Model :
GS43GS44
Features : Suitable for HVAC. Various installation types.
Sensor type : NDIR sensor
Measuring range : 2000 / 5000 / 10000 PPM
Output : 4 ... 20 mA + RS-485
Accuracy : ±40 or ±250 PPM ±3% of reading
IP rating : IP54(GS43) / IP64(GS44)
Sensor type : NDIR sensor
Measuring range : 2000 / 5000 / 10000 PPM
Output : 4 ... 20 mA + RS-485
Accuracy : ±40 or ±250 PPM ±3% of reading
IP rating : IP54(GS43) / IP64(GS44)
-
Features● Accurate and excellent long-term life cycle
● Measuring up to 10000 PPM
● Voltage or current output and optional RS-485, and display
● Free software configuration -
ApplicationsMonitoring air quality and saving energy / Environmental control and monitoring system / Ventilation system control for building, library, train station, supermarket, office / Agriculture, green houses, fruit and vegetable storage, mushroom farming, hatcheries and incubators
-
Download
-
Specification
Display
Display
Without backlight
Digit
5 digits(upon request)
Digit height
5.56 mm
Input
Sensor type
NDIR sensor
Measuring range
2000 / 5000 / 10000 PPM
Output
Output
4 ... 20 mA + RS-485
Signal connection
3-wire
Sensitivity
±1 PPM ±1% of measured value
Load resistance
Voltage output : ≧10 KΩ
Current output : < 250 Ωlinear accuracy (at +25°C)
400 ... 2000 PPM : ±40 PPM ±3% of reading
2000 ... 10000 PPM : ±250 PPM ±3% of readingOutput calibration (ZERO & SPAN)
Factory software calibration
Warm-up time
< 2 min. ; stable time 20 mins.
Response time(t90)
GS43: < 2 min. ; GS44 : < 6 min.
Sampling time
About 6 sec.
ADC default
2000 PPM : On;5000 PPM / 10000 PPM : Off
Environment
Medium
Non-aggressive gas(HVAC system)
Operating Temp.
0 ... 50°C
Operating Humid.
Tarps : 0 ... 95%RH(Non-condensing)
Non-woven : 0 ... 85%RH(Non-condensing)Storage temp.
-20 ... +60°C
Electrical
Power supply
DC 12 ... 36 V & AC 24 V ±10%
Current consumption
DC : 37 mA / AC : 70 mA
Starting current
DC : > 200 mA / AC : > 210 mA
Electrical connection
M12 (5P) connector with 2 m cable
Installation
Installation
Indoor : Wall mount
Duct : Flange mountProtection
IP rating
GS43 : IP54 / GS44 : IP64
Electrical protection
■ Reverse polarity
■ Over-voltage
■ Short-circuitCertification
Certification
CE
Material
Housing
PC fire-proof(PC - 110)(UL94V-2)
Filter for duct type
POM
Ventilation-cloth
2000 PPM : Non-woven
5000 / 10000 PPM : TarpsWeight
GS43 : 126 g / GS44 : 155 g
Note : Design and specifications are subject to change without notice.
Note : If the product has RS-485 function, to avoid damaging product, please make sure the product and the device which connect with RS-485 are on common ground.