• eYc DPT02 Signal Converter

eYc DPT02 Signal Converter

Features:Local display, easy keypad programming the signal output and scale, led for working status.
Accuracy : 0.2 % F.S. ± 1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input : voltage : 0 ... 5V ; 0 ... 10V ; Current : 0 ... 20mA ; 4 ... 20mA ; RTD : Pt100 / Pt1000, 2/3w
Output : voltage : 0 ... 5V ; 0 ... 10V ; Current : 0 ... 20mA ; 4 ... 20mA
Output signal : analog output / RELAY /RS-485
Model : eYc DPT02

Local display, easy keypad programming the signal output and scale, led for working status.
● Measuring input type : DC Current / DC Voltage / RTD
● More output type  :  Analog output / RS-485 / Relay / 2 Channel output 
● 20-point linear calibration function
● Signal isolation function : Power supply / Analog input / Analog output / RS-485
● Power supply : 85 ... 253 VAC;Auxiliary supply output ( 16 ... 25VDC / 23 mA )  : Use for 2-wire & 3-wire transmitter
● User-friendly. High light red LED display panel,  7.6 mm ( height of character ), 3 digits, -199 ... 999,  7-segment display
● DIN rail installation, High safety & stability, fire-proof case, moisture-proof cover
● Field : Chemical Industry / Energy / Water Circulation System / Oil & Gas / Marine / Factory Automation / Metal & Steel / Cement / Pulp & Paper / Pharmaceuticals / Food & Beverage
Display readout : 3 digits ( - 199 ... + 999 ) / decimal point : 0 ... 2 place
Display : highlight red LED ( 7-segment ) 
Digit height :  7.6 mm
Accuracy : 0.2 % F.S. ± 1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input : voltage : 0 ... 5V ; 0 ... 10V ; Current : 0 ... 20mA ; 4 ... 20mA ; RTD : Pt100 / Pt1000, 2/3w
Output : voltage : 0 ... 5V ; 0 ... 10V ; Current : 0 ... 20mA ; 4 ... 20mA 
Output signal : Analog output  / RELAY / RS-485
Load resistance : current : RL< 500 Ohm. ; voltage ≧ 10KΩ
Analogue output resolution : 16 bit
Signal error detection : yes

Relays
Alarm hysteresis : display value or 0 ... 100%
ON and OFF delay : 0 ... 3600s
Output signal error detection : yes     
Relay actuation direction : upper limit : HI, AL ; lower limit : LO, AL

Communication methods & protocol : RS-485 Modbus RTU, master or slave
RS-485 baud rate : 9600, 19200, 38400, 57600, 115200 bps
Operating environment : -10 ...  +60°C ; 0 ... 95% ( non-cond. )
Storage environment : -25 ...  +70°C
Power supply : 85 ... 253VAC
Auxiliary power : 16 .. 25VDC / 23mA
Insulation voltage endurance : 2KVac/1min 
Parameter memory type : FLASH
Dissipated power : 5W
Isolation : Power supply / Analog input / Analog output / RS-485
Protect degree : IP20
Electric protection : polarity protection & over-voltage
Certification : CE
Housing : ABS fire-proof class ( UL94V-0 )
Dimensions ( HxWxD ) : 99.5 x 25.5 x 104.2 mm
Weight : about 158g

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

*Please make sure the product and the device which connect with RS485 are on common ground, avoid damaged product. 

Option list
8205001010
Cold junction compensation resistor
Chemical Industry / Energy / Oil & Gas / Marine /
Water Circulation System / Factory Automation /
Metal & Steel / Cement / Pulp & Paper /
Pharmaceuticals / Food & Beverage