THM06 Industrial Temperature and Humidity Transmitter
Sensor type: Capacitive Humidity Sensor & Pt 100
Measuring range: -40, ..., +180℃
Output: 4, ..., 20 mA / 0, ..., 10 V / RS-485
Accuracy: Temperature ±0.15°C / Humidity ±2%RH
IP rating: IP67
-
Features
Features
Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
- IP67, Stainless steel SUS304, Pressure resistance 16 bar.
- 330° rotatable, lightweight, unrestricted installation.
- Optional on-site real-time display.
- Process temperature up to 180°C, custom up to 200°C (Optional).
- Output: Analog / RS-485.
- Wide measurement range, Temp.: -40 ... +180°C, Humidity : 0 ... 100%RH.
- Measuring parameters: relative humidity, dew point temperature, frost point temperature, wet bulb temperature, water vapor partial pressure, mixing ratio, absolute humidity and enthalpy.
THM06 has a sturdy outer housing and a wide range of applications. It is also suitable for use in harsh environmental conditions.
Capacitive sensor, high accuracy of temperature, and humidity measurement, fast response, fast recovery after condensation.
It is stability even in long-term high humidity, also it has temperature compensation and computer linear calibration temperature and humidity function, suitable for industrial process gas supply or consumption, compressed dry air flow, and consumption monitoring.Each physical quantity measuring range is calculated by converting the temperature and humidity of the product. The values are for reference only.
-
Applications
Applications
Semiconductor / Electronics / Steel industry / Chemical / Pharmaceutical / Biotechnology industry / Tobacco industry / Industrial process control (drying or humidification) / Environmentally controlled / High humidity storage / Food
-
Download
-
Specification
Specifications
Input
Signal type
Capacitive humidity sensor & Pt100
Temperature range
-40°C, ..., +180°C
Customized up to 200°C (Optional)Humidity range
0, ..., 100%RH (non-condensing)
*Please refer to physical quantity measuring range list
Output
Signal
4, ..., 20 mA / 0, ..., 10 V / RS-485
Signal connection
3-wire
Accuracy
Temperature
±0.15°C+0.002°C x tactualHumidity (0 ... 90%)
Nonlinear error: ±1.2%RHHysteresis error: ±0.8%RHRepeatability error: ±0.4%RHHumidity (90 ... 100%)
±2%RH
Reaction time t90 (at +25°C)
<20 sec (S.S. metal grid filter with mesh)<30 sec (Sintered filter)Load resistance
Current output: ≦ 500 ΩVoltage output: ≧ 100 KΩElectrical
Power supply
DC 24 V±10%
Current consumption
DC 24 V : 60 mAElectrical connections
M12 connector
Environmental
Medium
Air, or medium compatible with stainless steelTemp. Operating
-20, ..., +60°C (Body); -40, ..., +180°C (Probe)Humid. Operating
0 ... 90%RH (Body, non-condensing)Probe pressure
16 bars
Storage temperature
-20 ... +60°C
Installation
Installation
1/2" PT movable threadProtection
IP rating
IP67
Electrical protection
■Reverse polarity■Over-voltage■Short-circuitMaterial
Housing
SUS304
Weight
Metal: 318 g (without wire)