• eYc THM06 Industrial Grade High Temperature Multi-function Dew Point Transmitter【Preliminary】
  • eYc THM06 Industrial Grade High Temperature Multi-function Dew Point Transmitter【Preliminary】

eYc THM06 Industrial Grade High Temperature Multi-function Dew Point Transmitter【Preliminary】

Feature : Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
Input : ​capacitive humidity sensor & Pt100
Measurement range : ​-40 ... +120°C ;
Customized up to 150°C (Optional) ;
0 ... 100%RH (Non-condensing) ; -50 ... +60 dp°C
Output: ​4 ... 20 mA / 0 ... 10 V / RS-485
Signal connection : 3-wire
Accuracy :±0.15°C+0.002°C x t actual ;
0 ... 100%RH (Non-condensing) ; ±3dp°C ± (0.02%F.S./°C)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA
Model : eYc THM06

THM06 has a sturdy outer housing and a wide range of applications. It is also suitable for use in harsh environmental conditions. Capacitive sensor, high accuracy of temperature, and humidity measurement, fast response, fast recovery after condensation. It is stability even in long-term high humidity, also it has temperature compensation and computer linear calibration temperature and humidity function, suitable for industrial process gas supply or consumption, compressed dry air flow, and consumption monitoring.

Each physical quantity measuring range is calculated by converting the temperature and humidity of the product. The values are for reference only.

More potential product articles, welcome to visit the link below
eYc-Success-StoryeYc-FAQ

Product 【Preliminary】

Input : Capacitive humidity sensor & Pt100
Measurement range :
Temperature : -40°C ... +120°C ; customized up to 150°C (Optional) ; 
Humidity : 0 ... 100%RH (Non-condensing)
Dew point : -50 ... +60 dp°C
Absolute humidity : 0 ... 32767 ppm(v)
Signal connection : 4 ... 20 mA / 0 ... 10 V / RS-485
Signal connection : 3-wire
Accuracy :
Temperature : ±0.15°C+0.002°C x t actual
Humidity : 0 ... 100%RH (Non-condensing)
Dew point : ±3 dp°C ± (0.02%F.S. / °C)
Reaction time: t90 (Temperature: +25°C) < 30 seconds (SUS sintered filter)
Load resistance : current output : ≦ 500Ω / voltage output : ≧ 10KΩ
Medium : Air, or medium compatible with stainless steel
Operating environment :
Temperature : Body : -20 ... +60°C ; probe : -40 ... +120°C
Humidity : Body : 0 ... 90%RH (Non-condensing)
S.S. Proof pressure for probe : 10 bar (-40 ... +120°C)
Operating power : DC 24±10% V
Electrical connections : M12 metal connector
Installation : Metal quick connector
IP Rating : IP67
Electrical protection : ▪ Polarity reversal protection ▪ Over-voltage ▪ Short-circuit
Housing material : SUS304
Notes: 1. No display (Standard) with display (Optional).
Notes: 2. Probe size: 50 / 100 / 150 mm (Standard), other lengths can be customized.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

 ● IP67, Stainless steel SUS304, withstand voltage 10 bar.
 ● 330° Rotatable, lightweight, unrestricted installation.
 ● Optional on-site real-time display.
 ● Process temperature up to 120°C, Custom up to 150°C (Optional)
 ● Output : Analog / RS-485
 ● Wide measurement range, Temp. -40...+120°C, humidity 0 ... 100%RH,
 ● Dew point -50 ... +60 dp°C
 ● Measuring parameter : relative humidity, dew point temperature, frost point temperature, wet bulb temperature, water vapor partial pressure, mixing ratio, absolute humidity and enthalpy.
Semiconductor / Electronics / Steel industry / Food /
Chemical / Pharmaceutical / Biotechnology / Industry /
Tobacco industry / Industrial process control (drying or humidification) /
Environmentally controlled / High humidity storage