Hot wire type air velocity series product principle application
Hot wire type air velocity series product principle application

Principle and Applications of Hot-wire Thermal Mass Flow Meters

In industrial processes, energy management, and environmental measurement, gas flow and air velocity measurement are fundamental parameters. Among various technologies, the hot-wire thermal mass flow meter is widely used in industrial gas flow and air velocity measurement systems due to its high sensitivity, excellent low-velocity measurement capability, and fast response time.

Compared with traditional differential pressure or mechanical flow meters, hot-wire measurement technology can directly reflect changes in gas velocity. It also provides high resolution and good repeatability, making it highly valuable for industrial process control, energy-saving management, and exhaust system measurements.

Measurement Principle of Hot-wire Anemometers

The fundamental principle of a hot-wire anemometer is based on the heat transfer relationship between a heated sensing element and the flowing fluid. A metal wire inside the sensing element is electrically heated, raising its temperature above that of the surrounding gas. When airflow passes over the sensing element, part of the heat is carried away, causing the temperature of the hot wire to decrease.

Since the electrical resistance of the metal wire varies with temperature, measuring changes in resistance, voltage, or current allows the gas velocity to be calculated, which can then be converted into a gas flow signal.

In simple terms, the hot-wire measurement process can be summarized as follows:

  1. The sensing element is heated by electrical current
  2. Flowing gas removes heat from the hot wire
  3. The temperature of the hot wire changes
  4. The resistance variation is converted into an electrical signal
  5. The signal is processed and converted into velocity or flow rate

Therefore, the higher the airflow velocity, the more heat is removed, resulting in a more significant change in the sensor output signal.

Typical hot-wire anemometer working principle

Operating Modes of Hot-wire Anemometers

Depending on the control method, hot-wire anemometers can generally be classified into three types:

  • CVA (Constant Voltage Anemometer)
  • CCA (Constant Current Anemometer)
  • CTA (Constant Temperature Anemometer)

Among them, the CTA constant temperature anemometer is the most commonly used configuration. In this mode, the system adjusts the input current to maintain the hot wire at a constant temperature. When the airflow velocity changes, the electrical power required to maintain the constant temperature also changes. By measuring this power variation, the airflow velocity can be determined.

The thermal equilibrium relationship can be described by King’s law:

e² = a' + b'vn

Where:

  • e: sensor output voltage
  • a': zero-offset output term
  • b': sensor sensitivity
  • v: fluid velocity
  • n: constant, typically about 0.45–0.5

Using this relationship, the characteristic curve between sensor output and flow velocity can be established for signal conversion and calibration.

Characteristic curve between sensor output and flow velocity

Technical Characteristics of Hot-wire Thermal Mass Flow Meters

Compared with other gas flow measurement technologies, hot-wire thermal mass flow meters offer several advantages:

  • Low pressure loss
  • Wide measurement range
  • Excellent low-velocity measurement capability
  • High sensitivity
  • Fast response time
  • High repeatability
  • Good linearity
  • Relatively easy maintenance

In addition, hot-wire measurement technology provides excellent frequency response and spatial resolution, making it particularly suitable for analyzing turbulent flows or rapidly fluctuating airflow. Through temperature compensation and signal linearization, measurement stability and accuracy can be further improved in practical applications.

Industrial Applications of Hot-wire Thermal Mass Flow Meters

Because hot-wire technology can directly respond to changes in gas velocity, it is widely used in many industrial gas flow measurement scenarios.

Chemical and Process Industries

  • Process gas flow measurement
  • Gas flow control in sampling systems
  • Gas flow measurement in induced draft and exhaust systems

Metallurgy and Steel Industry

  • Blast furnace gas flow measurement
  • Coke oven gas flow control
  • Gas supply control in heat treatment furnaces

Power and Energy Systems

  • Combustion air flow measurement in boilers
  • Primary and secondary air control
  • Fuel gas distribution measurement

Environmental Protection and Emission Systems

  • Gas flow measurement in wastewater aeration systems
  • Flue gas flow measurement in stacks and ducts
  • Biogas utilization system measurement

Food and Pharmaceutical Industries

  • Airflow measurement in ventilation systems
  • Process gas control
  • Gas measurement in boilers and combustion systems

Oil and Gas Industry

  • Natural gas flow measurement
  • Flare gas monitoring
  • Gas leakage testing

Industrial Equipment and Compressed Air Systems

  • Compressed air flow measurement
  • Pipeline gas flow control
  • Process gas ratio control

Conclusion

Hot-wire thermal mass flow meters measure gas flow based on the principle of heat transfer caused by flowing gas. They can sensitively detect changes in airflow velocity and provide high resolution, fast response, and excellent repeatability. As a result, they are widely used in industrial gas flow measurement, process control, and environmental monitoring.

With the continued growth of industrial automation, energy management, and smart manufacturing, high-precision gas flow measurement technologies will play an increasingly important role in a wide range of applications.

Part of the content references the joint research project between National Taiwan University of Science and Technology and Yuden Control Technology – Automatic Linear Calibration System for Hot-wire Air Velocity Sensors