Thermal Mass Airflow Measurement White Paper | FTM06D Insertion vs. FDM06-I Venturi Principles, Design and Applications

A comparison of sensing position, flow-path design and signal processing to explain the differences between two thermal flow measurement architectures and how to select them.

In compressed-air systems, production equipment needs stable supply pressure, while operators need to know where air goes, when it is used and how much is consumed over time. As monitoring needs expand from the shop floor to production-line comparison, preventive maintenance, energy saving and cost management, sensing principles, installation requirements and data use must all be considered.

eyc-tech FTM06D uses an insertion probe to sense airflow directly inside a pipe. It suits applications that primarily need air-velocity monitoring and a measurement point installed through a pipe opening. FDM06-I combines a Venturi measuring section with hot-wire sensing and provides instantaneous and totalized flow for downstream management. Both can be integrated into larger systems, but they differ in how measurements are established and how the necessary data are obtained and used. [1][2]

1. From Stable Air Supply to Transparent Consumption

Pressure indicates supply conditions but cannot, on its own, reveal air consumption. When compressors continue supplying air, pressure may remain similar even as equipment demand rises or a pipeline leak develops. Reading only the pressure gauge can conceal changes in the air-supply load.

Two machines may have similar instantaneous flow at startup but very different daily consumption because of operating hours, standby practices and production cycles. Monitoring must move beyond “is air available?” to “how much is being used now?” and “how much was used over the period?”

Is supply sufficient?
Data to monitor
Pressure and fluctuations
What it helps determine
Whether supply meets equipment requirements
When does air demand change?
Data to monitor
Instantaneous flow and machine status
What it helps determine
Startup, peak and continuous consumption
Which periods or machines use more air?
Data to monitor
Totalized flow and time records
What it helps determine
Comparison by shift, equipment and production cycle
Where are energy-saving opportunities?
Data to monitor
Air consumption, electricity and production data
What it helps determine
Supply efficiency and consumption per unit of output

Flow monitoring can provide clues to abnormal operation. For example, persistent flow after production stops may prompt inspection of standby consumption, continuous blowing or leaks. The actual cause must still be verified against equipment status and on-site findings.

2. Air Velocity, Flow Rate and Totalized Flow

Air velocity describes how fast gas moves. Volumetric flow rate is the gas volume passing a cross-section per unit time, while totalized flow is the accumulated quantity over a period. These quantities are related, but they describe different information.

Under the same reference conditions, volumetric flow rate equals cross-sectional mean velocity multiplied by the internal cross-sectional area. Mean velocity is required: a single reading at an arbitrary location cannot simply be treated as the whole cross-section average. Insertion point, velocity profile and calibration relationship all matter when converting velocity to pipe flow.

Gas is compressible, and its volume changes with pressure and temperature. Actual volumetric flow in a pipe and standard volumetric flow converted to specified reference conditions must therefore not be mixed. Before comparing machines or time periods, confirm that instruments and downstream systems use the same reference pressure, temperature and units.

3. FTM06D Sensing Architecture: Insertion Air-Velocity Measurement

The insertion probe extends into the pipe through an installation port. Measurement representativeness depends on probe position, insertion depth, orientation and the on-site velocity profile. To convert velocity into total pipe flow, the correct internal pipe diameter must also be set, and the effects of flow distribution addressed according to installation requirements.

FTM06D insertion probe with animated airflowFTM06D TransmitterSUS304 movable threadSensing Tip Close-upFTM06D sensing tip close-upAirflow DirectionInsertion Probe
Installation CheckPressure, Sealing and Fastening
Position CheckInsertion Depth and Probe Direction
Measurement-Point SelectionAccount for Elbows, Valves and Branches

Installation concept only. Refer to the product manual and on-site requirements.

Measurement Principle: Directly Sensing Airflow-Induced Heat Transfer

FTM06D uses a hot-wire sensing principle. Its probe includes a reference element for medium temperature and a heated sensing element. Air passing the probe removes heat; changes in velocity change the heat transfer between the element and the gas.

The product uses constant-temperature anemometry (CTA). Changes in the heating power needed to maintain the specified thermal state are related to velocity, then converted into measured output through calibration and signal processing. This allows the probe to obtain air-velocity information directly from the pipe.

The basic operating principle of a hot-wire anemometer is to measure gas velocity through heat transfer between a heated element and the fluid. When current passes through a heater, such as a platinum-resistance sensing element, heat is generated. Passing air removes some heat and changes the element’s temperature or resistance. Measuring that change, or the power needed to maintain the set temperature, and applying calibration and gas-property information provides an estimate of velocity.

The heating element need not be a traditional metallic wire. Platinum resistors or other suitable resistance heaters can also be used, depending on sensor construction and control strategy.

Heated sensor and Wheatstone bridge animation with editable HTML labelsHeated ElementHeated SensorWheatstone BridgeServo AmplifierVoltage Signal
Heat-Transfer Sensing
Heat transfer changes as air passes the heated and temperature sensors.
Wheatstone Bridge
The bridge circuit compares electrical changes in the sensed signals.
Signal Processing
The servo amplifier processes the signal to produce the illustrated voltage output.

This is a conceptual illustration of the sensing principle. Refer to the product’s technical documentation for the actual sensing configuration and circuitry.

Figure 1. Thermal air-velocity measurement and constant-temperature control concept.

The principle diagrams explain measurement mechanisms, not the actual internal construction of the product.

4. FDM06-I Sensing Architecture: Venturi-Based Flow Measurement

FDM06-I is installed inline by connecting its complete measuring section into the pipeline. The Venturi flow path and sensing elements are integrated into that section, so insertion depth does not need to be adjusted on site. Flow direction, connection size and required straight pipe runs must still be checked to ensure suitable inlet conditions.

FDM06-I inline flow meter with animated airflowUpstream Straight RunDownstream Straight RunFDM06-I Flow MeterPipe JunctionPipe JunctionAirflow Direction
Flow DirectionFollow the flow arrow on the product
Pipe ConnectionsCheck pipe size, fittings and sealing
Installation SpaceAllow space for installation and maintenance

Installation concept only. Refer to the product manual and on-site requirements.

Measurement Principle: Venturi Differential Pressure and Heat Transfer

As gas passes the Venturi throat, its velocity rises and static pressure falls, generating a pressure difference between the inlet and throat. This differential pressure drives a small portion of the gas through an internal sensing passage, where the sensing element obtains a signal related to the main-pipe flow.

Venturi flow path showing upstream P1 and throat P2 differential pressureAir InletP1 Upstream PressureP2 Throat PressureThroatAir Outlet
Air Enters
Air enters from the wider upstream pipe section.
Throat Acceleration
As the passage narrows, air velocity increases.
Differential Pressure
A pressure difference forms between inlet P1 and throat P2.

This Venturi diagram illustrates the concept. Refer to the product’s technical documentation for actual sensor construction and flow conversion.

Measurement Principle: Converting Heat Transfer to Flow by Hot-Wire Sensing

The sensing passage uses hot-wire measurement technology. As gas passes the heated element, it changes heat transfer and distribution. Sensing elements detect those changes, which are combined with the Venturi flow-path design and product calibration to determine main-pipe flow.

Hot-wire sensing heat distribution animationAirflow DirectionT1 Upstream SensorHeated ElementT2 Downstream Sensor
Heated Element
The heater creates a local heat source and a measurable thermal profile.
Airflow Effect
As air moves left to right, heat is carried downstream.
Sensor Comparison
T1 and T2 detect upstream and downstream temperature changes.

This heat-transfer illustration is conceptual. Heat-field shapes and colors do not represent measured temperatures or CFD simulation results.

The principle diagrams explain measurement mechanisms, not the actual internal construction of the product.

In short, FTM06D inserts a probe into the main pipe to sense local airflow-related heat transfer directly. FDM06-I first creates a pressure difference using the Venturi geometry and then obtains a flow-related signal from heat transfer in its internal passage.

5. Installation Conditions and Data Reliability

Measurement quality depends on both instrument performance and field conditions. Selection should consider normal consumption, peak demand, the minimum flow of interest and the pipe layout—not just the connection size. A straight pipe run allows the flow profile to recover from disturbances caused by elbows, valves and other components.

Airflow Contact
FTM06D Insertion Type
The probe senses airflow directly in the main pipe
FDM06-I Inline Venturi Type
Hot-wire elements sense airflow in the internal passage
Field Installation
FTM06D Insertion Type
Insert the probe through an installation port and mounting fitting
FDM06-I Inline Venturi Type
Install a complete measuring section inline
Installation Requirements
FTM06D Insertion Type
Check insertion depth, orientation and internal pipe diameter
FDM06-I Inline Venturi Type
Check connection size, flow direction and installation length
Upstream Flow Profile
FTM06D Insertion Type
Avoid unrepresentative velocity-profile readings
FDM06-I Inline Venturi Type
Keep inlet flow within installation requirements
Pipeline Arrangement
FTM06D Insertion Type
Plan probe and mounting-fitting arrangement
FDM06-I Inline Venturi Type
Plan the straight runs and meter layout
Maintenance Access
FTM06D Insertion Type
Provide space to remove the probe and fitting
FDM06-I Inline Venturi Type
Provide space to remove the measuring section

Gas conditions also matter. Water droplets, oil contamination or deposits can change heat transfer; changes in gas composition may also invalidate an existing calibration relationship. This article focuses on dry compressed-air measurement. The same configuration must not automatically be applied to wet, corrosive or mixed gases without confirmation.

6. Temperature Compensation and Three-Cycle Verification

Thermal flow sensing uses heat exchange between the gas and sensing element. Therefore, medium temperature affects readings as well as velocity. FTM06D includes temperature compensation to reduce the influence of temperature changes on air-velocity measurement.

Temperature Compensation: Velocity Response at Different Temperatures

Key observation: Compare reference air velocity, reference temperature and transmitter readings across different temperature conditions to assess whether the measurement output follows changes in airflow velocity. The chart below illustrates the verification trend.

Reference velocity, reference temperature and instrument velocity are compared on the same time axis. Air velocity is increased and decreased while temperature is changed progressively, to observe whether the transmitter output continues to follow the reference velocity.

The reference and instrument velocity curves show similar trends, which can help examine temperature compensation. The focus is performance when temperature changes—not just agreement at one fixed temperature.

Figure 4 | Temperature Compensation Verification

Reference VelocityMeasured VelocityReference Temperature
6050403020100
Figure 4: Temperature-compensation trend curve (illustrative reconstruction)
04080120160

Time (s) | Shared schematic scale for velocity (m/s) and temperature (°C)

Reference and instrument velocities follow similar trends across changing temperature conditions.

Note: HTML trend illustration reconstructed from the appearance of the Word chart. It is not the original test dataset and must not be used to calculate accuracy or error.

Three-Cycle Linearity: Comparing Repeated Velocity Steps

Key observation: At 25°C, repeat three stepwise increases and decreases in air velocity to compare readings at each step, repeatability between cycles, and differences between upward and downward sequences. The chart below illustrates the verification trend.

The three-cycle linearity chart compares reference and instrument velocity during three repeated stepwise increases and decreases at 25°C.

Repeating the same sequence reveals how readings match at different velocity levels, how consistently the measurement behaves across cycles and whether rising and falling steps differ materially. The two curves remain close over the three cycles and provide a basis for assessing repeatability.

Figure 5 | Three-Cycle Linearity Verification

Reference VelocityMeasured Velocity
Cycle 1Cycle 2Cycle 3
706050403020100
Figure 5: Three-cycle stepwise air-velocity trend curve (illustrative reconstruction)
0150300450600750900

Time (s) | Air velocity (m/s) | Test at 25°C

The stepwise rising and falling sequence is repeated three times; the closely following curves illustrate measurement correspondence and repeatability.

Note: HTML trend illustration reconstructed from the appearance of the Word chart. It is not the original test dataset and must not be used to calculate accuracy or error.

Temperature compensation and three-cycle testing evaluate FTM06D from two perspectives: changing medium temperature and repeated velocity sequences. In practice, catalogue specifications and installation requirements must also be observed when applying these validation capabilities to field monitoring.

7. FDM06-I Data Integration: From Flow Signal to Consumption Records

FDM06-I displays instantaneous and totalized flow and can transmit both values through Modbus to PLC, HMI or an energy-management system. Instantaneous flow helps track current demand. Totalized flow supports consumption summaries by shift, day or machine, reducing the need for downstream accumulation logic.

Instantaneous Flow
Main Purpose
Track trends, load and peak demand
Define During Integration
Units, reference conditions, range and polling period
Totalized Flow
Main Purpose
Consumption by shift, day and equipment
Define During Integration
Scaling, reset, overflow and power-loss behavior
Time and Equipment ID
Main Purpose
Associate use with lines and production periods
Define During Integration
Time synchronization, point IDs and data sources
Communication Quality
Main Purpose
Distinguish abnormal readings from missing data
Define During Integration
Timeout flags, recovery and missing-value handling

When integrating systems, confirm flow units, reading intervals and how the totalizer handles resetting or power loss so that downstream records remain consistent with the local display.

8. Monitoring Layout: From Equipment to Zone Consumption

Measurement locations should reflect the intended management boundary. Points may be established at machine inlets, distribution branches or treated-air headers, provided gas and installation conditions are suitable.

At the equipment level, monitoring can compare production, standby and shutdown to see airflow changes under different operating conditions. Consider FTM06D where insertion velocity measurement is the priority; consider FDM06-I when an integrated flow section and totalized consumption are required, after checking the actual operating range.

Distribution branches can reveal differences in consumption across lines or plant areas. The FDM06-I totalizer supports shift and daily records. However, a rise in branch consumption must be interpreted alongside output, operating hours and new equipment; it does not automatically mean lower efficiency.

When comparing multiple points, the difference between header and branches is not necessarily all leakage. Receiver charging and discharging, unmonitored branches, drain or dryer consumption, unsynchronized time windows and measurement error can all contribute. Confirm the system boundary and identical time windows before narrowing the cause with branch isolation or field inspection.

CDA Supply Header

Monitor the main supply at a pipe section with suitable gas and installation conditions.

Production Zone Consumption

Compare air use across production zones, considering operating hours and output.

Equipment Airflow Monitoring

Compare velocity or flow trends during production, standby and shutdown.

Shift Consumption Reporting

Use the totalizer to generate consistent shift and daily consumption records.

Energy Management Integration

Combine consumption, power and machine operation data to track savings and costs.

9. Energy Management: Consumption, Savings and Cost Control

FTM06D is suitable for establishing velocity monitoring points through pipe installation openings. FDM06-I integrates instantaneous and totalized flow for period-based consumption. Their different installation and data characteristics support different levels of energy management.

Energy Saving: Find Waste and Track Improvements

Where an existing pipe can accommodate an insertion point, FTM06D can show velocity changes during production, standby and shutdown to identify clues of continued air consumption. To compare total use before and after an improvement, FDM06-I totalized flow provides a direct period total. Together with actual electricity records, energy savings can be assessed, and applicable electricity emission factors can be used to estimate the resulting change in emissions. [4]

Preventive Maintenance: Use Flow Trends to Plan Inspections

FTM06D can continuously monitor velocity at an equipment inlet or air-supply pipe, helping identify changing airflow under comparable operating conditions. FDM06-I can monitor instantaneous flow and period consumption together, identifying unexpected increases in usage. Combined with pressure and equipment status, these trends can guide inspections of pipes, valves and pneumatic equipment and support comparisons before and after maintenance.

Energy Profit Centers: Account for Consumption and Cost

For existing pipes suitable for insertion installation, FTM06D can provide flow information once internal diameter and measurement conditions are correctly configured, allowing downstream accumulation based on the selected output. If a meter totalizer should be read directly, FDM06-I reduces the need to build integration logic downstream. With agreed point ownership, electricity rates and cost-allocation rules, downstream systems can summarize air-related cost by line or department for energy profit-center management.

ESG and Carbon Accounting: Build Traceable Records

FTM06D and FDM06-I can provide velocity, flow or totalized-flow data, according to configuration, for analysing compressed-air use and tracking improvements. Use in energy management or carbon inventories also requires electricity consumption, relevant emission factors and the company’s management and accounting procedures.

10. Selection and Implementation Based on Measurement Goals

Selection can be narrowed by four questions: what must be answered, which installation methods are acceptable, what is the actual operating range and what downstream data are needed?

Direct In-Pipe Velocity Monitoring
Preferred Option
FTM06D Insertion Type
Verify Before Installation
Port, probe depth, direction and representative sensing
Add a Point to Existing Piping
Preferred Option
FTM06D Insertion Type
Verify Before Installation
Fitting installation, site conditions and flow profile
Record Flow and Totalized Consumption
Preferred Option
FDM06-I Inline Venturi Type
Verify Before Installation
Flow range, connections, pressure loss and totalizer reading
Production Consumption and System Integration
Preferred Option
Compare data and installation needs, including FDM06-I integration
Verify Before Installation
Communication registers, units, periods and counting data
Track Low Flow During Shutdown
Preferred Option
Verify each model’s performance at the required low flow
Verify Before Installation
Low-flow capability, error, cutoff settings and baseline use

FTM06D uses a direct insertion probe to measure airflow, providing a straightforward way to establish velocity monitoring points. Derived flow and downstream functions require correct configuration and selected outputs. FDM06-I combines a Venturi measuring section with instantaneous and totalized flow, facilitating consumption records and management integration. [1][2][3]

During commissioning, record measurement location, piping conditions, configuration, reference conditions and communication mapping. Verify local and downstream readings. Traceable measurement sources, data definitions and use procedures are essential for meaningful consumption analysis, preventive maintenance, cost allocation and energy-saving follow-up.

Technical References

Technical References

[1] eyc-tech FTM06D product page and catalogue, accessed October 21, 2026.

https://www.eyc-tech.com/ftm06d-thermal-mass-flow-transmitter

[2] eyc-tech FDM06-I product page, accessed October 21, 2026.

https://www.eyc-tech.com/fdm06-i-venturi-thermal-mass-flow-meter

[3] eyc-tech FDM06-I Modbus Protocol, 20250304.

https://zh-tw.eyc-tech.com/pdf/620346/eyc-tech-FDM06-I-Modbus-Protocol-20250304.pdf

[4] GHG Protocol Scope 2 Guidance, accessed October 28, 2026.

https://ghgprotocol.org/scope-2-guidance