eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 120 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-A Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Measuring range: Air : 0 ... 20 m/s ; 0 ... 40 m/s
Accuracy: ±3% 0 ... 20 m/s;±5% 0 ... 40 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS140 Hot Wire Air Velocity Transmitter

Features:Using Mass flow principle A better choice for HVAC engineering
Measuring range:0 ... 20 m/s
Minimum measuring range:0.2 m/s
Signal:4 ... 20 mA / DC 0 ... 10 V
Accuracy(+25°C):±3%F.S.
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM94/95 Industrial Grade High Accuracy Thermal Mass Flow Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or slightly corrosion compressed air
Input type:Pt20 / Pt300(Air velocity), Pt1000(Temp.)
Measuring range:0 ... 120 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Linear accuracy:±1.5%
Installation:Duct type / Remote type
IP rating:IP67
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS14 Thermal Air Velocity Transmitter

Features :Temperature compensation, linear adjustment function
Sensor : Thermal mass flow sensor
Measuring range : 20 m/s
Minimum measuring range : 0.2 m/s
Accuracy(at 25°C): ±5% F.S.
Signal : 4 ... 20 mA / DC 0 ... 10 V
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTC04 Hot Wire Thermal Flow Switch

Feature : Strong, wide measurement range, flexible for water, oil and gas measurement
Type : Resistance Temperature Detector (RTD)
Range 1. : Water : 1 ... 200 cm/s
Range 2. : Oil : 3 ... 300 cm/s
Range 3. : Gas Flow : 20 ... 2000 cm/s
Output Signal : PNP, NPN, Relay