eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 90 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc Formaldehyde Detector

Suitable for various indoor measurement
Lightweight and easy to carry
Type:Electrochemical sensor
Measuring range:0 ... 5 ppm(Note 1) / Continuous active sampling real-time detection
Output:Built-in Bluetooth 4.0 / APP software for mobile and pad and PC

eYc Particle Counter

Counting range:0.5 / 1 / 3 / 5 μm
Effective measurement range:<100,000 count/L
Flow:2.83 L/min
Communication:2 sets RS-485

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA DC​
Power : 4 ... 20 mA, 2-wire loop power​
Electrical connection : DIN 43650 plug / M12 connector​
Max. 330° turnable

eYc L051 Submersible Pressure Transmitter

Feature : Submersible Pressure Transmitter
Input type : Level
Output : 4 ... 20 mA
Measuring range : 0 ... 10 bar
Accuracy : ± 0.5 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THM86/87 Industrial Grade Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM06T Thermal Mass Flow Transmitter[Coming soon]

Output:4 ... 20 mA / 0 ... 10 V ; RS-485
Input:Resistance temperature detector (RTD)
Measuring range:Air:0 ... 40 m/s
Accuracy:Air (at 25°C):±5%F.S.(Option 3%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM94/95 Industrial Grade High Accuracy Thermal Mass Flow Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or slightly corrosion compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 120 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Linear accuracy:±1.5%
Installation:Duct type / Remote type
IP rating:IP67
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06 Thermal Mass Flow Transmitter

Feature:Different probes flexible use for slightly corrosive or pure air. Strong housing with analog and RS-485 output
Type:Resistance temperature detector
Range:Air:0 ... 40 m/s
Output Signa:Analog:4 ... 20 mA / 0 ... 10 V ; RS-485
Product Accuracy:Air (at 25°C):±10%F.S.(Option 5%)
Power Supply:DC 24 V±10%
IP rating:IP67
●Additional option:(ILAC / TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc HFUM Handheld Ultrasonic Flow Meter

Accuracy:±1%
Velocity range:0 ... ±10 m/s
Pipe size:DN15 ... DN6000 mm
Liquid temperature:-30 ... 160°C
Liquid type:Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid