eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 90 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc GS07 CO2 Transmitter

Output:RS-485 / 0 … 10 V / 4 … 20 mA
RS-485:Digital output with Modbus RTU protocol, 0 ... 6000 PPM​
Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 20,000 (PPM) (Max.:50,000 PPM)
Accuracy:±40 PPM±3% of reading(at 25°C)
IP rating:IP54(Clamp);IP65(Flange)

3-in-1 Multifunction CO2 Indoor Air Quality Large LED Display / Monitor / Indicator

Easy Handle CO2 Quality To Upgrade,
Work Efficiency in Jaunty breath
Real-Time, React Quickly, High Brightness LED
====================================
Features :
★ CO2 >> 0 ... 2000 PPM
★ Temperature >> 0 ... +50 °C
★ Humidity >> 0 ... 100 %RH
★ CO2 Indication >>☹☺(Emoticon)
★ Output >> RS-485
★ Monitor in Time >> LED Local Display
====================================

eYc DMB04 4-in-1 Multifunction Indoor Air Quality Large LED Display / Monitor / Indicator

Features : Tackle Invisible Killer PM2.5 To Reduce risk of cancers!
Let’s Create Healthy interior Environment!
Real-Time, React Quickly, High Brightness LED
PM2.5 : 0 ... 500 μg/m3
CO2 : 0 ... 2000 PPM
Temp. : 0 ... +50 °C
Humidity : 0 ... 100 %RH
CO2 Indication : ☹☺(Emoticon)
Indication : PMV Indication
Output : RS-485
Monitor in Time : LED Local Display

eYc Particle Counter

Counting range:0.5 / 1 / 3 / 5 μm
Effective measurement range:<100,000 count/L
Flow:2.83 L/min
Communication:2 sets RS-485

eYc DPM02 Multifunction Signal Display Monitor

Feature:Measuring input type : DC current / DC voltage, More output type:Analog output / Relay / RS-485, Extraction of square root(Input : Voltage, Current)
Display readout:5 digits(-9.9.9.9 ... +9.9.9.9.9), 7-segment display
Accuracy:0.1%F.S.±1 digital
Input, Output:0 ... 10 V, 4 ... 20 mA

eYc DPT02 Signal Converter

Features:Local display, easy keypad programming the signal output and scale, led for working status.
Accuracy : 0.2%F.S.±1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input & Output : Voltage 0...5 V / 0...10 V ; Current 0...20 mA / 4...20 mA
Output signal : Analog output / Relay / RS-485

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional

eYc GM33/GM34 CO Transmitter Wall / Duct Type

Features : Electrochemical Sensor with a long life,good long term stability and high accuracy. It has lower sensitivity to interferant gases.
Input : Electrochemistry CO Sensor
Output : 0 ... 1 V / 0 ... 5 V / 0 ... 10 V / 1 ... 5 V / 0 ... 20 mA /
4 ... 20 mA ; RS-485;RS-485 & Analog
linear accuracy ( at 25 ±2℃, 40 ±10% RH ) :
±3% of F.S. ( best zero-point )
Measuring range : on request

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THM86/87 Industrial Grade Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)