eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 90 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc P064 Digital Differential Pressure Transmitter

Features:High accuracy, anti-interference ability. For electric power and machinery manufacturing process control.
Measuring liquid, gas, vapor, liquid level.
Measuring range : 0.1 ... 25 bar
Pressure type : Differential pressure
Accuracy : 0.2% measuring range≦0.06 bar;0.1%=0.06 bar ... 0.4 bar;
0.075% measuring range≧0.4 bar
Type : Differential Pressure
Power output :4 ... 20 mA+HART®(10.5 ... 36 V, typical 24 V)
IP Rating : IP65

eYc P045 External Flush Diaphragm Pressure Transmitter

Relative Pressure:0.1 ... 400 bar
Input: 4 ... 20 mA
Housing:SUS 304/316L
Media Measured:Liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P047 Flush Diaphragm Pressure Transmitter

Measuring range:Relative pressure:-1 ... 250 bar;Absolute pressure:0 ... 250 bar
Accuracy:0.5%F.S.
Output:4 ... 20mA (12 ... 30VDC) / 0 ... 10V (12 ... 24VDC)
IP rating:IP65
Material:SS316
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)

eYc Ozone Analyzer

Note:This product only available in Taiwan, China and Hong Kong.
Applicable to measurement and analysis of environmental protection industries such as semiconductor, agriculture, water resources, etc.
UV-D photometric method determination of ozone concentration, traceable to NIST international standards
Measuring range:
Standard type(User-range):1000 ppmv
Standard type(Auto-range):1 ... 100 ppm
Resolution:
Standard type(User-range):Min. 0.1 ppmv at 1000 ppm
Standard type(Auto-range):Min. 0.1 ppbv at 1 ppm

eYc FCM06 Coriolis Mass Flow Meter

Communication interface:RS-485
Flow range:5 ... 200,000 kg/h
Accuracy:Up to ±0.1% (Optional)​
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM06T Thermal Mass Flow Transmitter[Coming soon]

Output:4 ... 20 mA / 0 ... 10 V ; RS-485
Input:Resistance temperature detector (RTD)
Measuring range:Air:0 ... 40 m/s
Accuracy:Air (at 25°C):±5%F.S.(Option 3%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06 Thermal Mass Flow Transmitter

Feature:Different probes flexible use for slightly corrosive or pure air. Strong housing with analog and RS-485 output
Type:Resistance temperature detector
Range:Air:0 ... 40 m/s
Output Signa:Analog:4 ... 20 mA / 0 ... 10 V ; RS-485
Product Accuracy:Air (at 25°C):±10%F.S.(Option 5%)
Power Supply:DC 24 V±10%
IP rating:IP67
●Additional option:(ILAC / TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THM80X Series Industrial Grade High Accuracy Temperature & Humidity Transmitter

Features : IP65 / Process temp.:up to 200°C / S.S. probe proof pressure:10 bar, metal connector
Input:Capacitive Humidity Sensor & Pt100 Ω A class
Measuring range:
THM801:-40 ... +80°C / THM802:-40 ... +120°C /
THM803:-40 ... +200°C(as request) ;
0 ... 100%RH;-40 ... +60dp°C
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy(at+25°C):Temp.:±0.15°C±0.002°C x t actul
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Temperature & Humidity / Dew point / Frost point /
Wet-bulb Temp. / Vapor pressure / Mixture ratio / Absolute humidity / Specific enthalpy
Input:Capacitive humidity sensor & Pt 100 class A
Output:Standard RS-485 or 2 analog output / 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH / Dew point - 40 ... + 60 dp°C / Other please refer to physical quantity measuring range list.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)TAF has mutual recognition arrangement with ILAC MRA