Paper / Printing

View:

eYc THS30X Series Multifunction Temperature & Humidity Transmitter (indoor/duct/remote/outdoor)

Features : Multifunction physical quantities ─
temperature & humidity / dew point / frost point /
wet-bulb temp. / vapor pressure /mixture ratio /
absolute humidity / specific enthalpy
Input : Capacitive Humidity Sensor & PT 100Ω class A
Output : standard RS-485 or 2 analog output
( 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V )
Linear Accuracy (at 25°C) :
temperature ± 0.2 °C ± 0.005 °C x t actua /
humidity ( at + 25 °C ) ± 2 %RH
Working Range Suggestion :
temperature 0 ... 50 °C ( THS301 );
- 40 ... + 80 °C ( THS302 / S304 / 307 ) /
humidity : 0 ... 100 %RH / dew point - 40 ... + 60 °C /
Other please refer to physical quantity measuring range list
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P046 OEM Piezoresistive Pressure Transmitter

For pressure, hydraulic & pneumatic equipment, Anti-interference, long-term stability, Provides multiple types of pressure connections
Measuring range : -1 ... 400bar
Pressure type : Relative pressure, absolute pressure
Output signal / Power supply : 4 ... 20mA, 0 ... 5V, 0 ... 10V (12 ... 30VDC) / 0.5 ... 4.5V R/M(5VDC)
Accuracy : ±0.5%F.S.(typ.)
Response time : < 4ms
Ambient Temp. : -20 ... 80°C
IP rating : IP65
●Additional option (ILAC/TAF) Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO/IEC 17025)

eYc FTM06 Hot wire thermal air velocity transmitter

Feature:Micro-corrosion air measurement. Strong housing with analog and RS-485 output.
Type:Resistance temperature detector
Range:Air:0 ... 60 m/s
Output Signa:Analog:4 ... 20 mA / 0 ... 10 V ; RS-485
Product Accuracy:Air(at 25°C):3%<60 m/s(Because the probe is affected by the operating Temp., there will be some error)
Power Supply:8 ... 35 VDC
●Additional option (ILAC/TAF) Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO/IEC 17025)

eYc LBM04 Float Level Transmitter

Features :
No impact on measuring from container inner pressure
Multiple outputs selectable
Easy to use, applicable to various medium
Stainless steel wetted parts

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P047 Flush Diaphragm Pressure Transmitter

Measuring range:Relative pressure:-1 ... 250 bar;Absolute pressure:0 ... 250 bar
Accuracy:0.5%F.S.
Output:4 ... 20mA (12 ... 30VDC) / 0 ... 10V (12 ... 24VDC)
IP rating:IP65
Material:SS316
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THG03 CO2 Temperature & Humidity Transmitter / Indoor type

Input : CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at +25 °C ;V = 24 VDC;101.3kPa ) :
CO2 ± 40 PPM ± 3 % of reading / Temperature ± 0.5 ℃ /
Humidity ± 5 % RH ( 30 ... 80 % RH )
Measuring Range : CO2 0 ... 2000 PPM / Temp. 0 ... 50 ℃ /
Humidity 0 ... 100 %RH ( non-cond.)
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P045 External Flush Diaphragm Pressure Transmitter

Relative Pressure:0.1 ... 400 bar
Input: 4 ... 20 mA
Housing:SUS 304/316L
Media Measured:Liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FCM06 Coriolis Mass Flow Meter

Communication interface : RS-485
Flow range : 5 ... 200,000 kg/h
Accuracy : Up to ±0.1%
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FGM04 Gear Flow Meter

Features :
Medium : Liquids
Accuracy (at 30cst ) : ± 0.5 % of reading ( turndown ratio of 1:10 ) ; ± 1 % of reading (measuring range )
Repeatability : ± 1 % of reading
Pressure rating : Stainless steel 420 bar ; Aluminum 100 bar