Metal housing

View:

eYc AFMT Average Flow Measuring Tube ( Pitot tube )

Feature:High temperature resistance Corrosion resistant, Anti-clogging Data convert to flow rate quickly
Duct-mounting type / Material:Stainless 316
Operating temperature:Max. 250°C
Length:4" ... 40"(100 ... 1000 mm)
Option:differencial pressure trainsmitter(Can measure flow)

eYc AFMS-160 S-type Pitot tube

Feature : High temperature resistance, Corrosion resistant, Anti-clogging, Data convert to flow rate quickly
Operating pressure : Max 10 bar
Operating temperature : 800°C
Measuring medium / coefficient : Air / flow coefficient(K):0.84

eYc P045 External Flush Diaphragm Pressure Transmitter

Relative Pressure:0.1 ... 400 bar
Input: 4 ... 20 mA
Housing:SUS 304/316L
Media Measured:Liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P047 Flush Diaphragm Pressure Transmitter

Measuring range:Relative pressure:-1 ... 250 bar;Absolute pressure:0 ... 250 bar
Accuracy:0.5%F.S.
Output:4 ... 20mA (12 ... 30VDC) / 0 ... 10V (12 ... 24VDC)
IP rating:IP65
Material:SS316
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)

eYc Particle Counter

Counting range:0.5 / 1 / 3 / 5 μm
Effective measurement range:<100,000 count/L
Flow:2.83 L/min
Communication:2 sets RS-485

eYc FEM06 Electromagnetic Flow Meter

Features:
Diameter:15 ... 800 mm(1/2" to 32")
Range:Velocity 0 ... 0.25 m/s min. ; 0 ... 12 m/s max.
Be applicable sewage, wastewater,chemical plants, food factory application
IP rating:IP65 for compact / remote version, and IP68 for remote version
Accuracy:± 0.5% of reading
Output:4...20 mA / Pulse ; 4...20 mA / Pulse & RS-485
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)

eYc L051 Submersible Pressure Transmitter

Feature : Submersible Pressure Transmitter
Input type : Level
Output : 4 ... 20 mA
Measuring range : 0 ... 10 bar
Accuracy : ± 0.5 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P063 Piezoresistive Differential Pressure Transmitter

Features:Welding and full-sealed construction, full stainless housing, compact size, easy installation
Sensor Type:Piezoresistive diaphragm
Measuring Range:0 ... 20 bar
Output:4 … 20 mA
Signal Connection:2-wire
Accuracy:±0.5% of F.S.

●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc P041 Pressure Transmitter

Sensor type:Piezoresistive diaphragm
Measuring range:Relative pressure:10 bar
Output:4 ... 20 mA ; 2-wire
Linear accuracy:±0.3% of F.S.
●Additional option(ILAC/TAF)Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO / IEC 17025)

eYc THM14EX EX-Series Temp. and Humidity Transmitter

Feature : Stable & Accurate Performance in Explosion Hazardous Areas
Input : Capacitive Humidity Sensor & PT 1000Ω
Output : 4 ... 20 mA
Range : -20 ... +80°C ; 0 ... 100 %RH
Accuracy : ±0.3°C+0.002°C x t actual ; ±2% RH(20 ... 80 %)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc SD03 Industrial Grade Integrated Indicator Transmitter Series

Feature : Industrial-grade Metal Meter/Can be connected to a 2-wire transmitter/Anti-interference Design/Multiple Input Type
Input : 4 ... 20 mA DC Temperature / Pressure / Differential pressure / Flow, etc.
Range : -1999 ... +9999
Accuracy : 0.2 % F.S
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA