Laboratory / Clean room

View:

eYc THS30X Series Multifunction Temperature & Humidity Transmitter (indoor/duct/remote/outdoor)

Features : Multifunction physical quantities ─
temperature & humidity / dew point / frost point /
wet-bulb temp. / vapor pressure /mixture ratio /
absolute humidity / specific enthalpy
Input : Capacitive Humidity Sensor & PT 100Ω class A
Output : standard RS-485 or 2 analog output
( 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V )
Linear Accuracy (at 25°C) :
temperature ± 0.2 °C ± 0.005 °C x t actua /
humidity ( at + 25 °C ) ± 2 %RH
Working Range Suggestion :
temperature 0 ... 50 °C ( THS301 );
- 40 ... + 80 °C ( THS302 / S304 / 307 ) /
humidity : 0 ... 100 %RH / dew point - 40 ... + 60 °C /
Other please refer to physical quantity measuring range list
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc PHM33 Industrial grade differential pressure transmitter

Feature:
Input:Thermo differential pressure module
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 1 ... 5 V / 2 ... 10 V / 0 ... 10 V
Range:0 ... 500 pa
Accuracy:± 0.5 % of F.S.
Display:Optional

eYc PMD33 Differential Pressure Transmitter

Feature:
Input:Piezoelectric differential pressure module
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 5 V / 0 ... 10 V
Range:±50 ... ±2500 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc THS88 High Pressure Dew Point Transmitter

Max. scaling range : -100 ... +60 dp°C
Linear accuracy(working range of dew point : -60 ... +60 dp°C) : ±2 dp°C (at +25°C) ± (0.02%F.S/°C)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS88 Plus High Pressure Dew Point Transmitter

Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp°C
Linear accuracy : ±2 dp°C
Max. Scaling range : Dew point : -100 ... +60dp°C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS13/14 Temperature & Humidity Transmitter Indoor/ Duct

Input type : Capacitive Humidity Sensor & PT1000Ω
Measuring Range : 0 ... 50°C ; 0 ... 100 %
Accuracy ( at 25 °C ) : ±0.3°C+0.002°C x tactual ; ±3% RH(20 ... 80 %)
Output : 4 ... 20mA / 2-wire
IP Rating : IP54(Sensor:IP20)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THR23 Temperature & Humidity Transmitter / Indoor type

Features : 2 analog outputs or Modbus RS-485 /
Optional analog output + RS-485 /
Data can be logged and transferred to pc via RS-485 function link free software
Input Sensor Type : Temp.&Humidity MEMS sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at + 25 °C ; V = 24VDC ) :
Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH )
Measuring Range :
Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH ( non-cond. )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)