Insert type

View:

eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 90 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc AFMT Average Flow Measuring Tube ( Pitot tube )

Feature:High temperature resistance Corrosion resistant, Anti-clogging Data convert to flow rate quickly
Duct-mounting type / Material:Stainless 316
Operating temperature:Max. 250°C
Length:4" ... 40"(100 ... 1000 mm)
Option:differencial pressure trainsmitter(Can measure flow)

eYc AFMS-160 S-type Pitot tube

Feature : High temperature resistance, Corrosion resistant, Anti-clogging, Data convert to flow rate quickly
Operating pressure : Max 10 bar
Operating temperature : 800°C
Measuring medium / coefficient : Air / flow coefficient(K):0.84

eYc THM14EX EX-Series Temp. and Humidity Transmitter

Feature : Stable & Accurate Performance in Explosion Hazardous Areas
Input : Capacitive Humidity Sensor & PT 1000Ω
Output : 4 ... 20 mA
Range : -20 ... +80°C ; 0 ... 100 %RH
Accuracy : ±0.3°C+0.002°C x t actual ; ±2% RH(20 ... 80 %)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc SD03 Industrial Grade Integrated Indicator Transmitter Series

Feature : Industrial-grade Metal Meter/Can be connected to a 2-wire transmitter/Anti-interference Design/Multiple Input Type
Input : 4 ... 20 mA DC Temperature / Pressure / Differential pressure / Flow, etc.
Range : -1999 ... +9999
Accuracy : 0.2 % F.S
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T Thermal Mass Flow Transmitter[Coming soon]

Output:4 ... 20 mA / 0 ... 10 V ; RS-485
Input:Resistance temperature detector (RTD)
Measuring range:Air:0 ... 40 m/s
Accuracy:Air (at 25°C):±5%F.S.(Option 3%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc SD06-T Industrial Grade Integrated Indicator Temperature Transmitter

High-performance Integrated Indicator Transmitter with Anti-interference Design
Input:Temperature
Output:4 ... 20 mA
Display range:-9999 ... 99999
Accuracy:<0.2%
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc TP04-SW RTD Temperature sensor

●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM06 Thermal Mass Flow Transmitter

Feature:Different probes flexible use for slightly corrosive or pure air. Strong housing with analog and RS-485 output
Type:Resistance temperature detector
Range:Air:0 ... 40 m/s
Output Signa:Analog:4 ... 20 mA / 0 ... 10 V ; RS-485
Product Accuracy:Air (at 25°C):±10%F.S.(Option 5%)
Power Supply:DC 24 V±10%
IP rating:IP67
●Additional option:(ILAC / TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory(TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THM06 Industrial Grade High Temperature Multi-function Dew Point Transmitter【Preliminary】

Feature : Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
Input : ​capacitive humidity sensor & Pt100
Measurement range : ​-40 ... +120°C ;
Customized up to 150°C (Optional) ;
0 ... 100%RH (Non-condensing) ; -50 ... +60 dp°C
Output: ​4 ... 20 mA / 0 ... 10 V / RS-485
Signal connection : 3-wire
Accuracy :±0.15°C+0.002°C x t actual ;
0 ... 100%RH (Non-condensing) ; ±3dp°C ± (0.02%F.S./°C)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA