Industrial grade

View:

eYc SD06 Integrated Indicator Temperature Transmitter

High-performance Integrated Indicator Transmitter with Anti-interference Design
Input:Temperature
Output:4 ... 20 mA
Display range:-9999 ... 99999
Accuracy:<0.2%
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus High Pressure Dew Point Transmitter

Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp°C
Linear accuracy : ±2 dp°C
Max. Scaling range : Dew point : -100 ... +60dp°C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS07 Temperature & humidity transmitter for probe type

Features : Industrial class sensor comes with high accuracy and long-term stability.
Input : Capacitive Humidity Sensor & Pt100
Output : Temp. RTD ( Pt100 / NTC10K ) /
Humidity 0 ... 10 V ; 4 ... 20 mA
Accuracy : Temp. ±0.3°C+ 0.002°C x t actual /
Humidity ( at +25°C ) ±3 %RH (30 ... 70 %RH ) of F.S. /
Humidity ( at +15 ... 35°C ) ±5 %RH ( 20 ... 80 %RH ) of F.S.
Measuring Range : 0 ... 50 °C;5 ... 95 %RH
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc SD03 Integrated Indicator Transmitter Series

Feature : Industrial-grade Metal Meter/Can be connected to a 2-wire transmitter/Anti-interference Design/Multiple Input Type
Input : 4 ... 20 mA DC Temperature / Pressure / Differential pressure / Flow, etc.
Range : -1999 ... +9999
Accuracy : 0.2 % F.S
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM94/95 Industrial Grade High Accuracy Thermo Air Velocity Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 20 / 0 ... 40 / 0 ... 60 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485
Linear accuracy:±1.5%(±3% of F.S.)
Installation:Duct type / Remote type
IP rating:IP67

eYc THM06 Industrial High Temperature Multi-function Dew Point Transmitter【Preliminary】

Feature : Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
Input : ​capacitive humidity sensor & Pt100
Measurement range : ​-40 ... +120°C ;
Customized up to 150°C (optional) ;
0 ... 100%RH (non-cond.) ; -50 ... +60dp°C
Output: ​4 ... 20mA / 0 ... 10V / RS-485
Signal connection : 3-wire
Accuracy :±0.15°C+0.002°C x t actual ;
0 ... 100%RH (non-cond.) ; ±3dp°C ± (0.02%F.S./°C)
●Additional option (ILAC/TAF) Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO/IEC 17025)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS88 High Pressure Dew Point Transmitter

Max. scaling range:-100 ... +60 dp°C
Linear accuracy(Operating range of dew point:-60 ... +60 dp°C):±2 dp°C(at +25°C)±(0.02%F.S. / °C)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA