Hot Products

View:

eYc FTM94/95 Industrial Grade High Accuracy Thermal Mass Flow Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or slightly corrosion compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 120 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485 / Impulse
Linear accuracy:±1.5%
Installation:Duct type / Remote type
IP rating:IP67
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06 Thermal Mass Flow Transmitter

Feature:Different probes flexible use for slightly corrosive or pure air. Strong housing with analog and RS-485 output
Type:Resistance temperature detector
Range:Air:0 ... 40 m/s
Output Signa:Analog:4 ... 20 mA / 0 ... 10 V ; RS-485
Product Accuracy:Air (at 25°C):±10%F.S.(Option 5%)
Power Supply:DC 24 V±10%
IP rating:IP67
●Additional option:(ILAC / TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory(TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THM80X Series Industrial Grade High Accuracy Temperature & Humidity Transmitter

Features : IP65 / Process temp.:up to 200°C / S.S. probe proof pressure:10 bar, metal connector
Input:Capacitive Humidity Sensor & Pt100 Ω A class
Measuring range:
THM801:-40 ... +80°C / THM802:-40 ... +120°C /
THM803:-40 ... +200°C(as request) ;
0 ... 100%RH;-40 ... +60dp°C
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy(at+25°C):Temp.:±0.15°C±0.002°C x t actul
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Industrial High Pressure Low Humidity Dew Point Transmitter

Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Temperature & Humidity / Dew point / Frost point /
Wet-bulb Temp. / Vapor pressure / Mixture ratio / Absolute humidity / Specific enthalpy
Input:Capacitive humidity sensor & Pt 100 class A
Output:Standard RS-485 or 2 analog output / 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH / Dew point - 40 ... + 60 dp°C / Other please refer to physical quantity measuring range list.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)TAF has mutual recognition arrangement with ILAC MRA

eYc PHM33 Industrial Grade Differential Pressure Transmitter

Range:0 ... 500 pa
Input:Thermo differential pressure module​
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V /1 ... 5 V / 2 ... 10 V / 0 ... 10 V​
Accuracy:± 0.5 % of F.S.
Display:Optional