Green industry

View:

eYc THG03 CO2 Temp. & Humidity Transmitter(Indoor)

Input:CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at +25°C;DC 24 V;101.3 kPa):
CO2±40 PPM±3% of reading / Temperature±0.5°C / Humidity±5%RH(30 ... 80% RH)
Measuring range:0 ... 2000 PPM / 0 ... 50℃ / 0 ... 100%RH(Non-condensing)
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc P047 Flush Diaphragm Pressure Transmitter

Measuring range:Relative pressure:-1 ... 250 bar;Absolute pressure:0 ... 250 bar
Accuracy:0.5%F.S.
Output:4 ... 20mA (12 ... 30VDC) / 0 ... 10V (12 ... 24VDC)
IP rating:IP65
Material:SS316
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)

eYc GM33/GM34 CO Transmitter for Wall / Duct Type

Input : Electrochemistry CO Sensor
Output : 0...1V / 0...5V / 0...10V / 1...5V / 0...20mA /4...20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 , 40 ± 10 % RH ):± 3 % of F.S. ( best zero-point )
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TGP03_THP03 Multifunction PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temperature MEMS / Humidity MEMS / CO2 NDIR / PM2.5 Infrared LED
Output : RS-485
Accuracy : Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH ( non-cond. ) /
CO2 0 ... 2000 PPM / PM2.5 0 ... 500 μg/m3
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THR23 Temperature & Humidity Transmitter / Indoor type

Features : 2 analog outputs or Modbus RS-485 /
Optional analog output + RS-485 /
Data can be logged and transferred to pc via RS-485 function link free software
Input Sensor Type : Temp.&Humidity MEMS sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at + 25 °C ; V = 24VDC ) :
Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH )
Measuring Range :
Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH ( non-cond. )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Temperature & Humidity / Dew point / Frost point /
Wet-bulb Temp. / Vapor pressure / Mixture ratio / Absolute humidity / Specific enthalpy
Input:Capacitive humidity sensor & Pt 100 class A
Output:Standard RS-485 or 2 analog output / 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH / Dew point - 40 ... + 60 dp°C / Other please refer to physical quantity measuring range list.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)TAF has mutual recognition arrangement with ILAC MRA