For Engineering/Equipment/Project Transmitter

Provide exclusive preferential prices and dedicated services for companies and individuals purchasing large quantities of goods.
Welcome to contact us directly.
View:

eYc FTS140 Hot Wire Air Velocity Transmitter

Features:Using Mass flow principle A better choice for HVAC engineering
Measuring range:0 ... 20 m/s
Minimum measuring range:0.2 m/s
Signal:4 ... 20 mA / DC 0 ... 10 V
Accuracy(+25°C):±3%F.S.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

Made in Taiwan

eYc THS130/140 Temperature & Humidity Transmitter for Indoor / Duct type

Input:MEMS sensor
Output:4 ... 20 mA / 0 ... 10 V
Signal connection:2-wire / 3-wire
Accuracy:± 0.5°C / ±5%RH(30 ... 80%RH)
Measuring range:0 ... 50°C / 0 ... 100%(Non-condensing)
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

Made in Taiwan

eYc THR03 Indoor Temperature & Humidity Transmitter

Input:MEMS
Output:4 ... 20 mA
Measuring range:0 ... 50°C / 0 ... 100%RH(Non-condensing)
Accuracy:±0.5°C(10 ... 45°C) / ±5%RH(30 ... 80%RH)
Signal connection:2-wire
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

Made in Taiwan

eYc THR23 Temperature & Humidity Transmitter / Indoor type

Input sensor type:MEMS
Output:0 ... 10 V / 4 ... 20 mA
Accuracy(at+25°C;DC 24 V):±0.5°C / ±5%RH(30 ... 80%RH)
Measuring range:0 ... 50°C / 0 ... 100%RH(Non-condensing)
Interface:RS-485+analog
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

Made in Taiwan

eYc THS07 Temperature & Humidity Transmitter for Probe Type

Features : Industrial grade class sensor comes with high accuracy and long-term stability.
Input : Capacitive Humidity Sensor & Pt100
Output : Temp. RTD ( Pt100 / NTC10K ) /
Humidity 0 ... 10 V ; 4 ... 20 mA
Accuracy : Temp. ±0.3°C+ 0.002°C x t actual /
Humidity ( at +25°C ) ±3 %RH (30 ... 70 %RH ) of F.S. /
Humidity ( at +15 ... 35°C ) ±5 %RH ( 20 ... 80 %RH ) of F.S.
Measuring Range : 0 ... 50 °C;5 ... 95 %RH
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS17 Temperature and Humidity Transmitter (Digital / Analog)

MOQ:100 PCS/YEAR
Feature : Semiconductor MEMS sensor, has nicer long-term stability of measuring and react quickly feature
Output : Digital / Analog / RS-485 ; 4...20mA (2-wire) ; 0...10V(3-wire)
Range : 0 ... 50 °C ; 0 ... 100 %RH(non-cond.)
Accuracy : ± 0.5 °C ; ± 5 %RH
Nice Stability : Non-cond. : Sensor Protected
Housing : SUS304 or PC Fire-proof
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS13/14 Temperature & Humidity Transmitter Indoor / Duct

MOQ:100 PCS/YEAR
Output:4 ... 20 mA / 2-wire
Input type:Capacitive humidity sensor & Pt1000 Ω
Accuracy(at 25°C):±0.3°C+0.002°Cxtactual;±3%RH(20 ... 80%)
Measuring range:0 ... 50°C;0 ... 100%RH
IP rating:IP54(Sensor:IP20)
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc TP04 Temperature Transmitter(2-wire for Duct Type)

Features:SS housing, all-in design with anti-condensation function and good heat dissipation.
Good measuring repeatability and anti-interference.
Input:Pt100
Output:DC 4 ... 20 mA;2-wire
Accuracy:±0.5% of F.S.
Temperature range:-50 ... + 50°C / -50...0°C / 0 ... 50°C / 0 ... 100°C / 0 ... 200°C or special range
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc TP04-S RTD Temperature sensor

Measuring range : -70 ... +200°C
Electrical connection : DIN 43650 ABS
Connection method : 2-wire ; 3-wire
Accuracy tolerance :
RTD Class A±(0.15 + 0.002 | t |) : - 40°C ... 200°C
Class B±(0.15 + 0.002 | t |) : - 70°C ... 200°C
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTS07 Hot Wire Air Velocity Transmitter

MOQ:50 PCS
Probe type、2-meter cable、Highly stability and repeatability
10 m/s;20 m/s ; DC 0 ... 10 V
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTS14 Air Velocity Transmitter

Output : 4 ... 20 mA / 0 ... 10 VDC
Air velocity measuring range : 20 m/s
Accuracy( +25°C ) : ± 5 % F.S. ( nonlinear error, hysteresis error,repeatability error )
Thermal sensitivity temp. error : 0.2 % / °C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTC04 Hot Wire Thermal Flow Switch

Feature : Strong, wide measurement range, flexible for water, oil and gas measurement
Type : Resistance Temperature Detector (RTD)
Range 1. : Water : 1 ... 200 cm/s
Range 2. : Oil : 3 ... 300 cm/s
Range 3. : Gas Flow : 20 ... 2000 cm/s
Output Signal : PNP, NPN, Relay