Food industry

View:

eYc R6 Thermocouple / Process Freezer Application

Wall Type, Process Freezer of Food Industrial
Resistance : Pt100 / Pt500 / Pt1000
Accuracy : A±(0.15+0.002 | t | ) ; B±(0.3 +0.005 | t | )
Junction Box : KF Cast, Aluminium(IP65)
Protect Tube Length : 115(mm)
Protect Tube material : SUS304

eYc TP04 2-wire Temperature Transmitter for Duct Type

Features:SS housing, all-in design with anti-condensation function and good heat dissipation.
Good measuring repeatability and anti-interference.
Input:Pt100
Output:4 ... 20 mA;2-wire
Accuracy:±0.5% of F.S.
Temperature range:-50 ... + 50°C / -50...0°C / 0 ... 50°C / 0 ... 100°C / 0 ... 200°C or special range
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc LBM04 Float Level Transmitter

Features :
No impact on measuring from container inner pressure
Multiple outputs selectable
Easy to use, applicable to various medium
Stainless steel wetted parts

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FEM06 Electromagnetic Flowmeter

Features:
Diameter:15 ... 800 mm ( 1/2" to 32" )
Range:Velocity 0 ... 0.25m/s min. ; 0 ... 12m/s max.
Be applicable sewage, wastewater,chemical plants, food factory application
Protection:IP67 for compact version ,and IP68 for remote version
Accuracy:± 0.5% of reading
Output:4...20mA / Pulse ; 4...20mA / Pulse & RS-485
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA DC​
Power : 4 ... 20 mA, 2-wire loop power​
Electrical connection : DIN 43650 plug / M12 connector​
Max. 330° turnable

eYc FCM06 Coriolis Mass Flow Meter

Communication interface : RS-485
Flow range : 5 ... 200,000 kg/h
Accuracy : Up to ±0.1%
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P064 Digital Differential Pressure / Pressure Transmitter

Features:High accuracy, anti-interference ability. For electric power and machinery manufacturing process control.
Measuring liquid, gas, vapor, liquid level.
Measuring range : 0.1 ... 25bar
Pressure type : Differential pressure
Accuracy : ±0.075%FS;±0.1%FS (typ.);±0.2%FS
Type : Differential Pressure
Power output : 4 ... 20mA、4 ... 20mA+HART®(10.5 ... 36V, Typical 24V)
IP Rating : IP65

eYc DPMF-M9 Flow Meter

Output:Analog / Communication / Switch
Input:Analog / Pulse
Accuracy:±0.2%FS. frequency : ±1 pulse (LMS), better than 0.2%
Measuring Range:-999999 ... 999999 for instantaneous flow;0 ... 99999999.9999 for totalizer
Recommended cut out dimensions:92x92 (mm ). Depth condition:Do not affect the wiring.​