• eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA
Model : eYc THS88 Plus

Upgrade 150% faster

Capable of temperature compensation and linear calibration
Industrial sensor with non-condensing. Pressure resistance:16 bar
High pressure, low humidity. Dew point scaling range:-100 ... +60 dp°C
Standard Modbus RTU protocol, RS-485 communication interface
High accuracy and long-term stability
More size of connector for different environment
Analog output:0 ... 1 V / 0 ... 5 V / 1 ... 5 V / 0 ... 10 V / 2 ... 10 V / 0 ... 20 mA / 4 ... 20 mA
Free programmable software which can adjust dew point range and provide more physical quantities
such as dew point, frost point, absolute humidity and so on

More potential product articles, welcome to visit the link below

eYc-Success-StoryeYc-FAQ

Input type:Capacitive humidity sensor & Pt100
Operating range of dew point:-60 ... +60 dp°C
Max. scaling range:Dew point:-100 ... +60 dp°C
Dew point switch to another physical quantity range:Frost point:-60 ... 0 fp°C;Absolute humid.(Volume)0 ... 50000 ppm/v;Absolute humid.(Weight)0 ... 50000 ppm/w
Output signal:Standard RS-485 & 1 analog output / 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Signal connection:3-wire
Modbus:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C) (Operating range of dew point:-60 ... +60 dp°C)
Load resistance:Current output:Max.500 Ω;Voltage output:Min.10 KΩ
Output calibration (ZERO & SPAN) adjustment range:Software
Response time t90 (Temp. at+25°C):<20 sec
Power supply:DC 8 ... 35 V&AC 10 ... 30 V
Current consumption:DC 24 V, 50 mA
Electrical connection:M12 connector
Medium:Air
Operating Temp. for housing:-40 ... +60°C
Operating Humid. for housing:0 ... 95%RH (Non-condensing)
Operating Temp. for probe:-40 ... +60°C
Storage temperature:-25 ... +60°C
Pressure resistance:16 bar
Installation:Metal connector
IP rating:IP65(Probe:IP20)
Electrical protection:■ Polarity protection ■ Over-voltage ■ Short-circuit
Housing:S.S.(SUS304)
Probe:S.S.(SUS304);SUS sintered filter(SUS316)
Weight:233 g
Factory setting
Measuring range of dew point:-100 ... +20°C
Output:4 ... 20 mA& standard RS-485

*Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect.
Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

Compressed air system / Freezer / Adsorption machine / Plastic dryer / Industrial drying process / Paper / Chemical process monitoring