Feature : Micro-corrosion water and air measurement. Strong housing with analog and RS-485 output.
Type : Resistance Temperature Detector
Range 1. : Water : 0 ... 3.0 m/s
Range 2. : Air : 0 ... 60 m/s
Output Signal : Analog : 4 ... 20mA / 0 ... 10V ; RS-485
Product Accuracy : Water:5% < 3.0 m/s ; Air:3% < 60 m/s
Power Supply : 8 ... 35 VDC
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Model : eYc FTM06

Micro-corrosion water and air measurement. 
Strong housing with analog and RS-485 output.

FTM06 is based on thermodynamic principle,  there are 2 temperature sensors inside the probe: one for  temperature measurement, the other one as a measuring conveyor after  heated. 
Temperature difference between the two as a basis for measuring flow rate. When the medium flow rate increases, the temperature difference decreases. 
The temperature difference converted to standard signal output after processed that is why flow rate can be measured by these two sensors. All-metal housing, suitable for a variety of pipe diameters.


  • Type : Resistance Temperature Detector (RTD)
  • Range :  Water : 0 ... 3.0 m/s ; Air : 0 ... 60 m/s
  • Output Signal :  Analog : 4 ... 20mA / 0 ... 10V ; RS-485
  • Product Accuracy : Water : 5% < 3.0 m/s ; Air : 3% < 60 m/s
  • Response time : about 2 secs.
  • Medium : Water and gas which is compatible with stainless steel
  • Power supply : 8 ... 35 VDC
  • Installation : Metal flange mount or metal quick connector
  • Protection : IP67
  • Material : Housing SUS304
  • Note 1. Probe 0~450mm (Normal lead time)
    Note 2. Probe 450~1000mm (at most), Please contact us for delivery and price.

eYc Flowmeter requirements questionnaire PDF download.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect.
 
Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

*Please make sure the product and the device which connect with RS485 are on common ground, avoid damaged product.



  • IP67
  • Resistance Temperature Detector
  • Analog and RS-485 output
  • Applicable micro corrosion water or air
  • Strong stainless steel housing, for a variety of harsh environments
  • Built-in with temperature compensation, accommodate quickly any environment
  • Industrial process gas supply, consumption and dry flow monitoring
  • Compressed air consumption measurement Buildings, Factories, Clean rooms, Hospitals, Semiconductors, Electronics, Paper, Printing, Textiles, Steel, Food, Chemicals, Pharmaceuticals, Biotechnology industries