• eYc FTE120 OEM Hot Wire Air Velocity Transmitter (duct type)

eYc FTE120 OEM Hot Wire Air Velocity Transmitter (duct type)

Features : Hot wire air velocity transmitter, RTD platinum resistance, low error
rate, high stability, reaction quality
Input : RTD Platinum Resistance
Output : 4 ... 20 mA; 0 ... 10 V
Range : 0 ...20 m/s
Accuracy : ± 3 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Model : eYc FTE120

The best choice for wind speed / flow monitoring
eYc FTE120 Hot wire anemometer speed transmitter, RT D platinum resistance, low error
rate, high stability, reaction quality.PC fire-rated polished plastic material casi ng, coloris easy to identify , suitable for indoor environmental monitoring.
Duct is for closed duct, proc ess pipelines, such as parking garage, petrochemic alplants VOC emissions, flue emissions and flow / velocity of fl ow monitoring.
Can be installed in hospitals or department stores HVAC sy stem equipment and other small space equipment, wards, operating rooms or food court area of t he air traffic management.



Sensor : RTD Platinum Resistance
Measuring range : 0 ...20 m/s
Min. measuring range : 0.2  m/s
Output : 4 ... 20 mA; 0 ... 10 V
Signal connection : 3 Wire
Load resistance : Voltage output ≧ 10 KΩ ; Current output ≦ 500 Ω 
Response time : Reach 90% of ultimate value within 3 sec.
Angular dependence : < 3% Measuring value (When the angle <10 %)
Accuracy : ± 3 % of F.S
Warm-up time : < 2 Min.,Stable time 20 mins.
Media measured : Ambient
Working Temp. :0 ... 50 °C
Working humidity : 95 %RH ( non - cond. )
Storage Temp. : -20 ... + 60 °C
Power supply : 8 ... 35 VDC & 8 ...30 VAC
Current consumption : DC 8V : 120mA,24V : 80mA AC 8V : 150mA,24V : 120mA
Instantaneous current : DC 8V : 350mA,24V : 300mA AC 8V : 350mA,24V : 180mA 
Overvoltage protection : DC : < 45V ; AC : < 40V
Electrical connection : 3-Wire : 3P Terminal ; Plastic cable gland
Installation : Duct-fixed seat
Protection rating : IP 54
Electrical protection :  Polarity protection  Over-voltage  Short-circuit
Certification : CE、ROHS
Material : Housing : PC , Fire-proof, HB class
                 Probe : SUS 304
                 Filter : PC+Glass fiber
Weight : 133 g

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect.
Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.
The best choice for wind speed / flow monitoring
● 
【Material】SUS304 stainless steel probe ,PC + glass fiber, temperature up to 120 ℃
● 【PC Housging】PC fire-resistant plastic cover, HB PC Fire retardant
● 【Cost–performance】Affordable,economic,high accuracy, long-term stability
● 【High stability】RTD platinum resistance, low error rate, high stability,reaction quality
● 【Easy installation】Compact size,simplicity style easy to install
● 【Electrical Protection】Reverse protection circuit
● 【Environmental Protection】CE certification and ROHS
HVAC Process Monitoring / Air Conditioning / Ventilation Control
Building / Plant / Cleanroom / Laboratory / Building Automation Environmental Monitoring
Agriculture / Food / Electronics / Industrial Monitoring
Residential / Hospital / Storage