• eYc FFM05 Liquid Turbine Flow Transmitter
  • eYc FFM05 Liquid Turbine Flow Transmitter
  • eYc FFM05 Liquid Turbine Flow Transmitter

eYc FFM05 Liquid Turbine Flow Transmitter

Flow range:0.04 ... 800(m3/h)
Accuracy:0.5% of rate (Optional:0.2%)
Output:Pulse, 4 … 20mA (Option:Local display+4 ... 20mA)
Material:SS304(Housing/Flanges) / 2Cr13(Rotor) / Tungsten Carbide(Bearings and shafts)
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA
Model : eYc FFM05

eYc-Success-StoryeYc-FAQ

Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units(Liters, cubic meters, gallons etc.)on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.
Measured value:Flow rate, Volume flow
Medium:Liquid:Water;Diesel, etc.(without impurity, low viscosity, flow conditions similar to EN 29104)
Temperature:+10 ... +30°C / +50 ... +86°F
Output:Pulse, 4 … 20 mA(Option:Local display+4 ... 20 mA)
Accuracy:0.5% of rate(Optional:0.2%)
Diameter:DN4 … DN200
Measuring ratio:Standard-10:1;Optional-20:1
Inlet section:≥10 DN
Operating pressure:1 bar
Installation conditions:Inlet run≥10 DN;Outlet run≥5 DN(Take care that flow sensor is always fully filled)
Flow direction:Forward(Arrow on flow sensor indicates flow direction)
Connection

Thread:DN4 … DN50(External);DN15 … DN50(Internal)
Flange(Optional):ANSI / JIS
Operating conditions
Process temperature:-20 ... +80°C / -20 ... +150°C
Ambient temperature(All versions):Standard(with aluminum converter housing):20 … +55°C
Storage temperature:-20 ... +70°C
Pressure:Thread:63 bar(DN4 … DN15) / 25 bar(DN20 … DN50)
                  Flange:16 bar
                  ANSI:150 Ib RF
                  JIS:10K
Material
Housing:SS304(Optional:SS316)
Flanges:SS304
Rotor:2Cr13(Optional:Duplex impeller)
Bearings and shafts:Tungsten carbide
Display meter:Standard:Polyurethane coated die-cast aluminum

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. 
Petroleum / Chemical engineering / Electric power and machinery fields