• eYc FEM06 Electromagnetic Flow Meter
  • eYc FEM06 Electromagnetic Flow Meter
  • eYc FEM06 Electromagnetic Flow Meter

eYc FEM06 Electromagnetic Flow Meter

Features:
Diameter:15 ... 800 mm(1/2" to 32")
Range:Velocity 0 ... 0.25 m/s min. ; 0 ... 12 m/s max.
Be applicable sewage, wastewater,chemical plants, food factory application
IP rating:IP65 for compact / remote version, and IP68 for remote version
Accuracy:± 0.5% of reading
Output:4...20 mA / Pulse ; 4...20 mA / Pulse & RS-485
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)
Model : eYc FEM06

● Flow velocity range : 0...12 m/s
● Be applicable sewage, wastewater, chemical plants, food factory application
● IP68 enclosure that can be used for underground applications
● FEP liner suitable in vacuum tube
● High accuracy of ±0.5% of reading
● Empty pipe, current excitation

High accuracy for a wide range of process conditions


FEM06 Electromagnetic Flow Meter is a flange type electromagnatic flow meter ideal for conductive liquids. It comes in sizes from 15 ... 800 mm flow tubes.
Electromagnetic Flow meter is widely used for tap-water, waste water, food & beverage pulp & paper and many other applications.
Can be is a stand alone magmeter that could also be used with various configurations, such integral or remote and AC or DC power requirement. RS-485 communications are available.

More potential product articles, welcome to visit the link below
eYc-Success-StoryeYc-FAQ
Diameter : 15 ... 800 mm ( 1/2" to 32" )
Range : Velocity 0 ... 0.25 m/s min. ; 0 ... 12 m/s max.
Material : Measuring Tube : Stainless Steel 304
                Flange : Cabon Steel ( Standard ) ; Stainless Steel 304 ( Option )
                Housing : Carbon Steel ( Standard ) ; Stainless Steel 304 ( Option )
IP rating : IP65 for compact / remote version, and IP68 for remote version
Conductivity : To be more than 20 μS/cm
Power Supply : DC 24 V, AC 220 V 50 Hz
Output : 4...20 mA / Pulse ; 4...20 mA / Pulse & RS-485
Electrode : SUS316L ; Hastelloy ; Titanium ; Tantalum
Process Connection : Flange
Flange type : ANSI、DIN、JIS
Ambient Temp. : - 25 ... + 65 °C
Accuracy( Velocity ≧ 0.3 ... 12 m/s ) : 
± 0.5% of reading ( 15 ... 600 mm ) 
1 % of reading ( 700 ... 800 mm )

eYc Flow meter requirements questionnaire PDF download.

*Please make sure the product and the device which connect with RS485 are on common ground, avoid damaged product.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

High viscous fluids / Corrosive and abrasive liquids process industry, waste water treatment, chemical industry, steel industry, mining,pulp & paper, irrigation, power generation.