Energy saving

View:

eYc THM86/87 Industrial Grade Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc GM33/GM34 CO Transmitter for Wall / Duct Type

Input : Electrochemistry CO Sensor
Output : 0...1V / 0...5V / 0...10V / 1...5V / 0...20mA /4...20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 , 40 ± 10 % RH ):± 3 % of F.S. ( best zero-point )

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc PMD33 Differential Pressure Transmitter

Feature:
Input:Piezoelectric differential pressure module
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 5 V / 0 ... 10 V
Range:±50 ... ±2500 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc L051 Submersible Pressure Transmitter

Feature : Submersible Pressure Transmitter
Input type : Level
Output : 4 ... 20 mA
Measuring range : 0 ... 10 bar
Accuracy : ± 0.5 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Temperature & Humidity / Dew point / Frost point /
Wet-bulb Temp. / Vapor pressure / Mixture ratio / Absolute humidity / Specific enthalpy
Input:Capacitive humidity sensor & Pt 100 class A
Output:Standard RS-485 or 2 analog output / 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH / Dew point - 40 ... + 60 dp°C / Other please refer to physical quantity measuring range list.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)TAF has mutual recognition arrangement with ILAC MRA