Energy / Renewable energy

View:

eYc FCM06 Coriolis Mass Flow Meter

Communication interface : RS-485
Flow range : 5 ... 200,000 kg/h
Accuracy : Up to ±0.1%
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THR23 Temperature & Humidity Transmitter / Indoor type

Input sensor type:MEMS
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at+25°C;DC 24 V):±0.5°C / ±5%RH(30 ... 80%RH)
Measuring range:0 ... 50°C / 0 ... 100%RH(Non-condensing)
Modbus:RS-485
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THG03 CO2 Temp. & Humidity Transmitter(Indoor)

Input:CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at +25°C;DC 24 V;101.3 kPa):
CO2±40 PPM±3% of reading / Temperature±0.5°C / Humidity±5%RH(30 ... 80% RH)
Measuring range:0 ... 2000 PPM / 0 ... 50℃ / 0 ... 100%RH(Non-condensing)
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Temperature & Humidity / Dew point / Frost point /
Wet-bulb Temp. / Vapor pressure / Mixture ratio / Absolute humidity / Specific enthalpy
Input:Capacitive humidity sensor & Pt 100 class A
Output:Standard RS-485 or 2 analog output / 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH / Dew point - 40 ... + 60 dp°C / Other please refer to physical quantity measuring range list.
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)TAF has mutual recognition arrangement with ILAC MRA