Electronic machinery

View:

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc TP01 2-wire RTD Temperature Transmitter for Head-mounting Type

Features:In this way, a stable and accurate figure can be collected and shown on the display of terminal instrument
Input:Pt100(3-wire)
Output:DC 4 ... 20 mA;2-wire
Accuracy:±0.1% of F.S.
Temperature Range:-50 ... +50°C / -50 ... 0°C / 0 ... 50°C / 0 ...100°C / 0 ... 200°C / special span
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM84/85 Industrial Grade High Accuracy Thermal Air Velocity Transmitter

Features:LCD, display air velocity and temperature
Sensor Type:Thermal mass flow sensor
Air Velocity Measuring Range:0.15 ... 90 m/s
Air Velocity min. Measuring Range:0.15 m/s
Temp. Sensor / Measuring Range:Pt1000, 0 ... 80°C
Accuracy(+25°C):Air velocity:±1.5%F.S.
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THM80X Series Industrial Grade High Accuracy Temperature & Humidity Transmitter

Input:Capacitive Humidity Sensor & Pt100 Ω A class
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Measuring range:
THM801:-40 ... +80°C / THM802:-40 ... +120°C / THM803:-40 ... +200°C(as request) ; 0 ... 100%RH;-40 ... +60dp°C
Accuracy(at+25°C):
Temperature : ±0.15°C±0.002°Cxtactual
Humidity ( 0 ... 90 %RH ) : Nonlinear error:±1.2%RH / Hysteresis error:±0.8%RH / Repeatability error:±0.4%RH
Humidity ( 90 ... 100 %RH) : ±2%RH
IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS30X Series Multifunction Temperature & Humidity Transmitter(Indoor/Duct/Remote/Outdoor)

Features:Industrial sensor comes with high accuracy and long-term stability
Input:Capacitive humidity sensor & Pt 100 class A
Output:RS-485 or 2 analog output / 4 ... 20 mA / 0 ... 10 V
Linear accuracy(at 25°C):Temperature ±0.2°C±0.005°Cxtactual / Humidity (at+25°C)±2%RH
Operating range suggestion:Temperature 0 ... 50°C(THS301);- 40 ... + 80°C(THS302 / 304 / 307) / Humidity 0 ... 100%RH
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc DST01 Universal Isolating Signal Converter / Splitter

Signal isolation:Power supply;Analog input
3 groups of analog output
1 set RS-485 output
Accuracy:±0.05% of span ±0.0025% / °C
Output signal:4 ... 20 mA, DC 0 ... 10 V