Duct

View:

eYc GM33/GM34 CO Transmitter for Wall / Duct Type

Input : Electrochemistry CO Sensor
Output : 0...1V / 0...5V / 0...10V / 1...5V / 0...20mA /4...20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 , 40 ± 10 % RH ):± 3 % of F.S. ( best zero-point )
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS13/14 Temperature & Humidity Transmitter Indoor/ Duct

Input type : Capacitive Humidity Sensor & PT1000Ω
Measuring Range : 0 ... 50°C ; 0 ... 100 %
Accuracy ( at 25 °C ) : ±0.3°C+0.002°C x tactual ; ±3% RH(20 ... 80 %)
Output : 4 ... 20mA / 2-wire
IP Rating : IP54(Sensor:IP20)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P041 Pressure Transmitter

Output:4 ... 20mA ; 2-wire
Linear accuracy:± 0.3 % of F.S.
Media measured:air / liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P045 External Flush Diaphragm Pressure Transmitter

Relative Pressure:0.1 ... 400 bar
Input: 4 ... 20 mA
Housing:SUS 304/316L
Media Measured:Liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS14 Air Velocity Transmitter

Output : 4 ... 20 mA / 0 ... 10 VDC
Air velocity measuring range : 20 m/s
Accuracy( +25°C ) : ± 5 % F.S. ( nonlinear error, hysteresis error,repeatability error )
Thermal sensitivity temp. error : 0.2 % / °C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS130/140 Temperature & Humidity Transmitter for Indoor / Duct type

Features : Voltage or current outputs, optional passive temperature output
Input : MEMS sensor
Output : 4 ... 20 mA / 0 ... 10V
Signal Connection : 3-wire
Accuracy : ± 0.5°C / ± 5% RH ( 30....80 %RH )
Measuring Range : 0 ... 50 °C / 0 ... 100 % (non-condensing)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)