Display

View:

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA(2-Wire) / 0 ... 10V(3-Wire)
Electrical connection: DIN 43650: 330° / M12: 210°
Accuracy: 0.2%F.S.
Display: On-site display / 4 ... 20 mA / 0 ... 10V

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc PMD330 Differential Pressure Transmitter (Indoor)

Feature:Silicon chips on differential pressure module of MEMS integration technology
Input:Piezoelectric differential pressure module
Output:4 ... 20 mA / 0 ... 10 V
Measuring range:±50 ... ±10000 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-A Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Measuring range: Air : 0 ... 20 m/s ; 0 ... 40 m/s
Accuracy: ±3% 0 ... 20 m/s;±5% 0 ... 40 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc DPT02 Signal Converter

Feature:Local display, easy keypad programming the signal output and scale,LED for working status
Display readout:3 Digits(-199 ... +999)
Output signal:Analog output, Relay, RS-485
Accuracy:0.2%F.S.±1 digital
Sampling time:4 cycle / sec

eYc TGP03 Multifunction CO2/PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temperature MEMS / Humidity MEMS / CO2 NDIR / PM2.5 Infrared LED
Output : RS-485
Accuracy : Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH (Non-condensing) /
CO2 0 ... 2000 PPM / PM2.5 0 ... 500 μg/m3

eYc GS43/44 CO2 Transmitter(Indoor / Duct Type)

Feature: Accurate and excellent long-term life cycle. Measuring up to 10000 PPM
Sensor type:NDIR sensor
Output:4 ... 20 mA / 0 ... 10 V
linear accuracy(at +25°C):400 ... 2000 PPM:±40 PPM ±3% of reading / 2000 ... 10000 PPM:±250 PPM ±3% of reading
Measuring range : 2000 / 5000 / 10000 PPM
Display : Optional

eYc DPM02 Multifunction Signal Display Monitor

Feature:Measuring input type : DC current / DC voltage, more output type:Analog output / Relay / RS-485, extraction of square root(Input : voltage, current)
Display readout:5 digits(-9.9.9.9 ... +9.9.9.9.9), 7-segment display
Accuracy:0.1%F.S.±1 digital
Input&Output:Current / Voltage

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc DMB04 4-in-1 Multifunction Indoor Air Quality Large LED Display / Monitor / Indicator

Features : Tackle Invisible Killer PM2.5 To Reduce risk of cancers!
Let’s Create Healthy interior Environment!
Real-Time, React Quickly, High Brightness LED
PM2.5 : 0 ... 500 μg/m3
CO2 : 0 ... 2000 PPM
Temp. : 0 ... +50 °C
Humidity : 0 ... 100 %RH
CO2 Indication : ☹☺(Emoticon)
Indication : PMV Indication
Output : RS-485
Monitor in Time : LED Local Display