Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA
Note:This product only available in Taiwan, China and Hong Kong.
Applicable to measurement and analysis of environmental protection industries such as semiconductor, agriculture, water resources, etc.
UV-D photometric method determination of ozone concentration, traceable to NIST international standards
Measuring range:
Standard type(User-range):1000 ppmv
Standard type(Auto-range):1 ... 100 ppm
Resolution:
Standard type(User-range):Min. 0.1 ppmv at 1000 ppm
Standard type(Auto-range):Min. 0.1 ppbv at 1 ppm
Features:Local display, easy keypad programming the signal output and scale, led for working status.
Accuracy : 0.2%F.S.±1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input & Output : Voltage 0...5 V / 0...10 V ; Current 0...20 mA / 4...20 mA
Output signal : Analog output / Relay / RS-485
Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)
Suitable for various indoor measurement
Lightweight and easy to carry
Type:Electrochemical sensor
Measuring range:0 ... 5 ppm(Note 1) / Continuous active sampling real-time detection
Output:Built-in Bluetooth 4.0 / APP software for mobile and pad and PC