Display

View:

eYc SD06 Integrated Indicator Temperature Transmitter

High-performance Integrated Indicator Transmitter with Anti-interference Design
Input:Temperature
Output:4 ... 20 mA
Display range:-9999 ... 99999
Accuracy:<0.2%
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc HFUM Handheld Ultrasonic Flow Meter

Accuracy:±1%
Velocity range:0 ... ±10 m/s
Pipe size:DN15 ... DN6000 mm
Liquid temperature:-30 ... 160°C
Liquid type:Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid

eYc THG03 CO2 Temp. & Humidity Transmitter(Indoor)

Input:CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at +25°C;DC 24 V;101.3 kPa):
CO2±40 PPM±3% of reading / Temperature±0.5°C / Humidity±5%RH(30 ... 80% RH)
Measuring range:0 ... 2000 PPM / 0 ... 50℃ / 0 ... 100%RH(Non-condensing)
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA DC​
Power : 4 ... 20 mA, 2-wire loop power​
Electrical connection : DIN 43650 plug / M12 connector​
Max. 330° turnable

eYc DPT02 Signal Converter

Features:Local display, easy keypad programming the signal output and scale, led for working status.
Accuracy : 0.2%F.S.±1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input & Output : Voltage 0...5 V / 0...10 V ; Current 0...20 mA / 4...20 mA
Output signal : Analog output / Relay / RS-485

eYc PMD33 Differential Pressure Transmitter

Feature:
Input:Piezoelectric differential pressure module
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 5 V / 0 ... 10 V
Range:±50 ... ±2500 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc DPM02 Multifunction Signal Display Monitor

eYc TGP03_THP03 Multifunction PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temperature MEMS / Humidity MEMS / CO2 NDIR / PM2.5 Infrared LED
Output : RS-485
Accuracy : Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH ( non-cond. ) /
CO2 0 ... 2000 PPM / PM2.5 0 ... 500 μg/m3
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc GS23 CO2 Transmitter / Indoor type

Input :Data can be logged and transferred to pc via RS-485 function link free software. 1 analog output or Modbus RS-485. Optional LCD display.
Input : NDIR sensor
Output : 0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy ( at +25 °C ;101.3 kPa ) : ± 40 PPM ± 3 % of reading
Measuring Range : 0 ... 2000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FEM06 Electromagnetic Flowmeter

Features:
Diameter:15 ... 800 mm ( 1/2" to 32" )
Range:Velocity 0 ... 0.25m/s min. ; 0 ... 12m/s max.
Be applicable sewage, wastewater,chemical plants, food factory application
Protection:IP67 for compact version ,and IP68 for remote version
Accuracy:± 0.5% of reading
Output:4...20mA / Pulse ; 4...20mA / Pulse & RS-485
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)