Chemical / Pharmaceutical / Food industry / Medical biotechnology

View:

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA(2-Wire) / 0 ... 10V(3-Wire)
Electrical connection: DIN 43650: 330° / M12: 210°
Accuracy: 0.2%F.S.
Display: On-site display / 4 ... 20 mA / 0 ... 10V

eYc FTM06D Thermal Mass Flow Transmitter

Output:One group output, Analog(4 ... 20 mA / 0 ... 10 V)+RS-485 or Impulse+RS-485
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 120 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-A Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Measuring range: Air : 0 ... 20 m/s ; 0 ... 40 m/s
Accuracy: ±3% 0 ... 20 m/s;±5% 0 ... 40 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc L051 Submersible Pressure Transmitter

Feature : Submersible Pressure Transmitter
Input type : Level
Output : 4 ... 20 mA
Measuring range : 0 ... 10 bar
Accuracy : ± 0.5 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TGP03/THP03 Multifunction CO2/PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temperature MEMS / Humidity MEMS / CO2 NDIR / PM2.5 Infrared LED
Output : RS-485
Accuracy : Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH (Non-condensing) /
CO2 0 ... 2000 PPM / PM2.5 0 ... 500 μg/m3
Display : Optional

eYc GM33/GM34 CO Transmitter Wall / Duct Type

Features : Electrochemical Sensor with a long life,good long term stability and high accuracy. It has lower sensitivity to interferant gases.
Input : Electrochemistry CO Sensor
Output : 0 ... 1 V / 0 ... 5 V / 0 ... 10 V / 1 ... 5 V / 0 ... 20 mA /
4 ... 20 mA ; RS-485;RS-485 & Analog
linear accuracy ( at 25 ±2℃, 40 ±10% RH ) :
±3% of F.S. ( best zero-point )
Measuring range : on request

eYc GS43/44 CO2 Transmitter Indoor / Duct Type

Input : NDIR sensor
Output : 4 ... 20mA / 0 ... 20mA / 0 ... 10V / 0 ... 5V / 0 ... 1V
linear accuracy ( at +25 °C ) :
400 ... 2000 PPM:± 40 ppm ± 3 % of reading /
other : ± 50 PPM ± 3 % of reading
measuring range : 2000 / 5000 / 10000 PPM
Display : Optional

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc DMB04 4-in-1 Multifunction Indoor Air Quality Large LED Display / Monitor / Indicator

Features : Tackle Invisible Killer PM2.5 To Reduce risk of cancers!
Let’s Create Healthy interior Environment!
Real-Time, React Quickly, High Brightness LED
PM2.5 : 0 ... 500 μg/m3
CO2 : 0 ... 2000 PPM
Temp. : 0 ... +50 °C
Humidity : 0 ... 100 %RH
CO2 Indication : ☹☺(Emoticon)
Indication : PMV Indication
Output : RS-485
Monitor in Time : LED Local Display