Chemical / Pharmaceutical

View:

eYc P064 Digital Differential Pressure Transmitter

Features:High accuracy, anti-interference ability. For electric power and machinery manufacturing process control.
Measuring liquid, gas, vapor, liquid level.
Measuring range : 0.1 ... 25 bar
Pressure type : Differential pressure
Accuracy : 0.2% measuring range≦0.06 bar;0.1%=0.06 bar ... 0.4 bar;
0.075% measuring range≧0.4 bar
Type : Differential Pressure
Power output :4 ... 20 mA+HART®(10.5 ... 36 V, typical 24 V)
IP Rating : IP65

eYc THM86/87 Industrial Grade Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FUM05B Wall Mounted Ultrasonic Flowmeter

Feature :
Measurement accuracy 1 %
Converter protection class IP 67 , transducer protection class IP 68
Wide measurement range , pipe size from DN15mm to DN6000mm
Connect the temperature transducer can finish the heat / energy measurement
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM06T Thermal Mass Flow Transmitter[Coming soon]

Output:4 ... 20 mA / 0 ... 10 V ; RS-485
Input:Resistance temperature detector (RTD)
Measuring range:Air:0 ... 40 m/s
Accuracy:Air (at 25°C):±5%F.S.(Option 3%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06D Thermal Mass Flow Transmitter[Coming soon]

Output:4 ... 20 mA / 0 ... 10 V ; RS-485
Input:Resistance temperature detector (RTD)
Measuring range:Air:0 ... 60 m/s
Accuracy:Air (at 25°C):±3%F.S.(Option 1.5%)
IP rating:IP65
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc FCM06 Coriolis Mass Flow Meter

Communication interface:RS-485
Flow range:5 ... 200,000 kg/h
Accuracy:Up to ±0.1% (Optional)​
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc Particle Counter

Counting range:0.5 / 1 / 3 / 5 μm
Effective measurement range:<100,000 count/L
Flow:2.83 L/min
Communication:2 sets RS-485

eYc Ozone Analyzer

Note:This product only available in Taiwan, China and Hong Kong.
Applicable to measurement and analysis of environmental protection industries such as semiconductor, agriculture, water resources, etc.
UV-D photometric method determination of ozone concentration, traceable to NIST international standards
Measuring range:
Standard type(User-range):1000 ppmv
Standard type(Auto-range):1 ... 100 ppm
Resolution:
Standard type(User-range):Min. 0.1 ppmv at 1000 ppm
Standard type(Auto-range):Min. 0.1 ppbv at 1 ppm

eYc THM14EX EX-Series Temp. and Humidity Transmitter

Feature : Stable & Accurate Performance in Explosion Hazardous Areas
Input : Capacitive Humidity Sensor & PT 1000Ω
Output : 4 ... 20 mA
Range : -20 ... +80°C ; 0 ... 100 %RH
Accuracy : ±0.3°C+0.002°C x t actual ; ±2% RH(20 ... 80 %)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc P063 Piezoresistive Differential Pressure Transmitter

Features:Welding and full-sealed construction, full stainless housing, compact size, easy installation
Sensor Type:Piezoresistive diaphragm
Measuring Range:0 ... 20 bar
Output:4 … 20 mA
Signal Connection:2-wire
Accuracy:±0.5% of F.S.

●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc P047 Flush Diaphragm Pressure Transmitter

Measuring range:Relative pressure:-1 ... 250 bar;Absolute pressure:0 ... 250 bar
Accuracy:0.5%F.S.
Output:4 ... 20mA (12 ... 30VDC) / 0 ... 10V (12 ... 24VDC)
IP rating:IP65
Material:SS316
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory (TAF Accreditation: 3032)