CDA system / Equipment / Factory

View:

eYc THS30X Series Multifunction Temperature & Humidity Transmitter (indoor/duct/remote/outdoor)

Features : Multifunction physical quantities ─
temperature & humidity / dew point / frost point /
wet-bulb temp. / vapor pressure /mixture ratio /
absolute humidity / specific enthalpy
Input : Capacitive Humidity Sensor & PT 100Ω class A
Output : standard RS-485 or 2 analog output
( 0 ... 20 mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 0 ... 10V )
Linear Accuracy (at 25°C) :
temperature ± 0.2 °C ± 0.005 °C x t actua /
humidity ( at + 25 °C ) ± 2 %RH
Working Range Suggestion :
temperature 0 ... 50 °C ( THS301 );
- 40 ... + 80 °C ( THS302 / S304 / 307 ) /
humidity : 0 ... 100 %RH / dew point - 40 ... + 60 °C /
Other please refer to physical quantity measuring range list
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P046 OEM Piezoresistive Pressure Transmitter

For pressure, hydraulic & pneumatic equipment, Anti-interference, long-term stability, Provides multiple types of pressure connections
Measuring range : -1 ... 400bar
Pressure type : Relative pressure, absolute pressure
Output signal / Power supply : 4 ... 20mA, 0 ... 5V, 0 ... 10V (12 ... 30VDC) / 0.5 ... 4.5V R/M(5VDC)
Accuracy : ±0.5%F.S.(typ.)
Response time : < 4ms
Ambient Temp. : -20 ... 80°C
IP rating : IP65
●Additional option (ILAC/TAF) Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO/IEC 17025)

eYc DPM02 Multifunction Signal Display Monitor

eYc THS88 High Pressure Dew Point Transmitter

Max. scaling range : -100 ... +60 dp°C
Linear accuracy(working range of dew point : -60 ... +60 dp°C) : ±2 dp°C (at +25°C) ± (0.02%F.S/°C)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS88 Plus High Pressure Dew Point Transmitter

Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp°C
Linear accuracy : ±2 dp°C
Max. Scaling range : Dew point : -100 ... +60dp°C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THM86/87 Industrial Multifunction Dew Point Transmitter

Features : With temperature compensated and linear correction / Physical quantity & temperature linear correction output by computer program / Industrial class sensor comes with high accuracy, long-term stability,and anti-condensation function.
Input : Capacitive Humidity Sensor & Pt100Ω
Output : 0...20mA / 4...20mA / 0...5V / 0...10V
Linear accuracy ( at + 25°C ) : ±0.15°C ± 0.002 °C x tactual / ±3dp°C ± ( 0.02 % F.S / °C )
Temp. influence of body ( at + 25 °C ) : 0.02 % F.S. / °C
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA DC​
Power : 4 ... 20 mA, 2-wire loop power​
Electrical connection : DIN 43650 plug / M12 connector​
Max. 330° turnable

eYc FPC04 Flow Switch-Piston Type

Feature:
Hysteresis:Depends on switching point, minimum 0.6 L / min
Medium:Water, Oil, Gas
Connection mode:Connector specification M12
Pressure resistance:Stainless steel : 100 bar, Plastic : 10 bar