eYc DPM02 Multifunction Signal Display Monitor

eYc THS88 Plus High Pressure Dew Point Transmitter

Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp°C
Linear accuracy : ±2 dp°C
Max. Scaling range : Dew point : -100 ... +60dp°C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc DPT02 Signal Converter

Features:Local display, easy keypad programming the signal output and scale, led for working status.
Accuracy : 0.2%F.S.±1 digital
Sampling time : 4 cycle / sec
Response time adjustment range : 0.5 ... 60 sec
Input & Output : Voltage 0...5 V / 0...10 V ; Current 0...20 mA / 4...20 mA
Output signal : Analog output / Relay / RS-485

eYc THR23 Temperature & Humidity Transmitter / Indoor type

Input sensor type:MEMS
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at+25°C;DC 24 V):±0.5°C / ±5%RH(30 ... 80%RH)
Measuring range:0 ... 50°C / 0 ... 100%RH(Non-condensing)
Modbus:RS-485
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc THG03 CO2 Temp. & Humidity Transmitter(Indoor)

Input:CO2 NDIR sensor / Temp. & humidity MEMS sensor
Output:0 ... 5 V / 0 ... 10 V / 4 ... 20 mA
Accuracy(at +25°C;DC 24 V;101.3 kPa):
CO2±40 PPM±3% of reading / Temperature±0.5°C / Humidity±5%RH(30 ... 80% RH)
Measuring range:0 ... 2000 PPM / 0 ... 50℃ / 0 ... 100%RH(Non-condensing)
Display:Optional
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc GM33/GM34 CO Transmitter for Wall / Duct Type

Input : Electrochemistry CO Sensor
Output : 0...1V / 0...5V / 0...10V / 1...5V / 0...20mA /4...20mA ; RS-485;RS-485 & analogue
linear accuracy ( at 25 ± 2 , 40 ± 10 % RH ):± 3 % of F.S. ( best zero-point )
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc THS17 Temperature and humidity transmitter (Digital / Analog)

Feature : Semiconductor MEMS sensor, has nicer long-term stability of measuring and react quickly feature
Output : Digital / Analog / RS-485 ; 4...20mA (2-wire) ; 0...10V(3-wire)
Range : 0 ... 50 °C ; 0 ... 100 %RH(non-cond.)
Accuracy : ± 0.5 °C ; ± 5 %RH
Nice Stability : Non-cond. : Sensor Protected
Housing : SUS304 or PC Fire-proof
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THM06 Industrial High Temperature Multi-function Dew Point Transmitter【Preliminary】

Feature : Adaptation to high temperature and high humidity conditions or harsh environments such as chemical pollution & condensation
Input : ​capacitive humidity sensor & Pt100
Measurement range : ​-40 ... +120°C ;
Customized up to 150°C (optional) ;
0 ... 100%RH (non-cond.) ; -50 ... +60dp°C
Output: ​4 ... 20mA / 0 ... 10V / RS-485
Signal connection : 3-wire
Accuracy :±0.15°C+0.002°C x t actual ;
0 ... 100%RH (non-cond.) ; ±3dp°C ± (0.02%F.S./°C)
●Additional option (ILAC/TAF) Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO/IEC 17025)

eYc THM80X series Industry degree high accuracy temperature & humidity transmitter

Features : IP65 protection degree / Process temp. : up to 200℃ / S.S. probe proof pressure : 10 bar, metal connector
Input : Capacitive Humidity Sensor & PT 100Ω A class
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / 0 ... 10 V
Accuracy ( at +25 °C ) :
temperature : ± 0.15 °C ± 0.002 °C x t actul /
humidity ( 0 ... 90 % ) : nonlinear error : ± 1.2 % RH ; hysteresis error : ± 0.8 % RH ; repeatability error : ± 0.4 % RH /
humidity ( 90 ... 100 %) : ± 2 % RH /
thermal sensitivity temperature error : 0.05 % RH / °C
Factory Uncertainty ( at +25 °C ) :
temperature uncertainty : 0.14 °C / humidity uncertainty : 0.4 % RH ( >10 % ... 20 % ) ; 0.65 % RH ( >20 % ... 90 % ) ; 0.97 % RH ( >90 % ... 98 % )
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTM94/95 Industrial Grade High Accuracy Thermo Air Velocity Transmitter

Feature:Suitable for harsh environments, industrial processes flow monitoring or compressed air
Input type:Pt20 / Pt300(Air velocity),Pt1000(Temp.)
Measuring range:0 ... 20 / 0 ... 40 / 0 ... 60 Nm/s
Output signal:4 ... 20 mA / 0 ... 10 V / RS-485
Linear accuracy:±1.5%(±3% of F.S.)
Installation:Duct type / Remote type
IP rating:IP67
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 High Pressure Dew Point Transmitter

Max. scaling range:-100 ... +60 dp°C
Linear accuracy(Operating range of dew point:-60 ... +60 dp°C):±2 dp°C(at +25°C)±(0.02%F.S. / °C)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA