3-wire

View:

eYc FTM06D Thermal Mass Flow Transmitter

Output:4 ... 20 mA+RS-485 / 0... 10 V+RS-485 / Impulse+RS-48
Input:Thermal mass flow sensor
Measuring range:Air:0 ... 120 m/s
Accuracy:±1.5% F.S.
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTS34/35 Air Velocity Transmitter

Features:Linear calibration function
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : Air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / DC 0 ... 10 V
Display:Optional
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06C-A Thermal Mass Air Velocity and Air Volume Transmitter

Output:4 ... 20 mA & RS-485 / 0 ... 10 V & RS-485 / RS-485 & Impulse
Input:Pt20/Pt300 (Air velocity) / Pt1000 (Temp.)
Measuring range:0 ... 5 m/s ~ 0 ... 60 m/s
Accuracy:±1.5% (Option±1%)
IP rating:IP65
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc THS88 Plus Industrial High Pressure Low Humidity Dew Point Transmitter

Features:Speed Upgrade 150%
Input:Capacitive humidity sensor & Pt100
Output:Standard RS-485 & 1 analog output
Linear accuracy:±2 dp°C(at +25°C)±(0.02%F.S. / °C)
Operating range of dew point:-60 ... +60 dp°C
Max. Scaling range:Dew point:-100 ... +60 dp°C
Pressure resistance:16 bar
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc PMD330 Differential Pressure Transmitter (Indoor)

Feature:Silicon chips on differential pressure module of MEMS integration technology
Input:Piezoelectric differential pressure module
Output:4 ... 20 mA / 0 ... 10 V
Measuring range:±50 ... ±10000 pa
Accuracy:±2.0% of F.S.
Display:Optional

eYc GM33 CO Transmitter(Wall Type)

Feature:Electrochemical Sensor with a long life, good long term stability and high accurac
Sensor type:Electrochemistry CO Sensor
Output:0 ... 10 V / 4 ... 20 mA / RS-485 / RS-485 & analog
linear accuracy (at25 ±2℃, 40 ±10% RH ):± 3 % of F.S. (Best zero-point)
Measuring range:On request
Operating range:0 ... 500 PPM

eYc FTM06T-W Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Range: Water 0 ... 1.5 m/s;0 ... 3 m/s
Accuracy: ±3% 0 ... 1.5 m/s;±5% 1.5 ... 3 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc FTM06T-A Thermal Mass Type Air Velocity and Flow Transmitter

Output signal: Analog / RS-485 / Impulse output
Input signal type: Thermal mass flow sensor
Measuring range: Air : 0 ... 20 m/s ; 0 ... 40 m/s
Accuracy: ±3% 0 ... 20 m/s;±5% 0 ... 40 m/s
IP rating:IP65 (IP67 optional)
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc TGP03 Multifunction CO2/PM2.5 Indoor Air Quality Monitor

Features : Real-Time Data of PM2.5, CO2, temperature & humidity. / Anti-condensation and nicer long-term stability.
Input : Temperature MEMS / Humidity MEMS / CO2 NDIR / PM2.5 Infrared LED
Output : RS-485
Accuracy : Temperature ± 0.5 °C / Humidity ± 5 %RH ( at 30 ... 80 %RH ) /
CO2 ± 40 PPM ± 3 % of Reading / PM2.5 ± 10 μg/m3 ± 5% of Reading
Measuring Range : Temperature 0 ... 50 °C / Humidity 0 ... 100 %RH (Non-condensing) /
CO2 0 ... 2000 PPM / PM2.5 0 ... 500 μg/m3

eYc GS43/44 CO2 Transmitter(Indoor / Duct Type)

Feature: Accurate and excellent long-term life cycle. Measuring up to 10000 PPM
Sensor type:NDIR sensor
Output:4 ... 20 mA / 0 ... 10 V
linear accuracy(at +25°C):400 ... 2000 PPM:±40 PPM ±3% of reading / 2000 ... 10000 PPM:±250 PPM ±3% of reading
Measuring range : 2000 / 5000 / 10000 PPM
Display : Optional

eYc TP01 Temperature Transmitter(2-Wire RTD Head-Mounting Type)

Features:Linearised temperature measurement with Pt100 sensor
Input:RTD Pt100 Ω(3-wire)
Output:DC 4 ... 20 mA(2-wire)
Accuracy:±0.1% of F.S.
Temperature Range:-50 ... 400°C or special range
●YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report, for more detailed information please contact us.
(TAF accreditation:3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA

eYc TP02 Temperature Transmitter for DIN-rail Type

Product features:Special IC for RTD;high accuracy is assured.High quality and low price.
Input:RTD Pt100(3-wire)
Output:DC 4...20 mA(2-wire)
Accuracy:0.1% of F.S.
Temperature range:-50...+50°C / 0...50°C / 0...100°C/0...200°C / Special range