2-wire

View:

eYc P064 Digital Differential Pressure Transmitter

Features:High accuracy, anti-interference ability. For electric power and machinery manufacturing process control.
Measuring liquid, gas, vapor, liquid level.
Measuring range : 0.1 ... 25 bar
Pressure type : Differential pressure
Accuracy : 0.2% measuring range≦0.06 bar;0.1%=0.06 bar ... 0.4 bar;
0.075% measuring range≧0.4 bar
Type : Differential Pressure
Power output :4 ... 20 mA+HART®(10.5 ... 36 V, typical 24 V)
IP Rating : IP65

eYc P045 External Flush Diaphragm Pressure Transmitter

Relative Pressure:0.1 ... 400 bar
Input: 4 ... 20 mA
Housing:SUS 304/316L
Media Measured:Liquid
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc TP01 2-wire RTD Temperature Transmitter for Head-mounting Type

Features:In this way, a stable and accurate figure can be collected and shown on the display of terminal instrument
Input:Pt100(3-wire)
Output:DC 4 ... 20 mA;2-wire
Accuracy:±0.1% of F.S.
Temperature Range:-50 ... +50°C / -50 ... 0°C / 0 ... 50°C / 0 ...100°C / 0 ... 200°C / special span
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc SD05 Integrated Signal Indicator

Input signal : 4 ... 20 mA DC​
Power : 4 ... 20 mA, 2-wire loop power​
Electrical connection : DIN 43650 plug / M12 connector​
Max. 330° turnable

eYc L051 Submersible Pressure Transmitter

Feature : Submersible Pressure Transmitter
Input type : Level
Output : 4 ... 20 mA
Measuring range : 0 ... 10 bar
Accuracy : ± 0.5 % of F.S.
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc P041 Pressure Transmitter

Sensor type:Piezoresistive diaphragm
Measuring range:Relative pressure:10 bar
Output:4 ... 20 mA ; 2-wire
Linear accuracy:±0.3% of F.S.
●Additional option(ILAC/TAF)Test report - Standard calibration laboratory (TAF accreditation:3032, using ISO / IEC 17025)

eYc THM14EX EX-Series Temp. and Humidity Transmitter

Feature : Stable & Accurate Performance in Explosion Hazardous Areas
Input : Capacitive Humidity Sensor & PT 1000Ω
Output : 4 ... 20 mA
Range : -20 ... +80°C ; 0 ... 100 %RH
Accuracy : ±0.3°C+0.002°C x t actual ; ±2% RH(20 ... 80 %)
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc SD03 Industrial Grade Integrated Indicator Transmitter Series

Feature : Industrial-grade Metal Meter/Can be connected to a 2-wire transmitter/Anti-interference Design/Multiple Input Type
Input : 4 ... 20 mA DC Temperature / Pressure / Differential pressure / Flow, etc.
Range : -1999 ... +9999
Accuracy : 0.2 % F.S
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc SD06-T Industrial Grade Integrated Indicator Temperature Transmitter

High-performance Integrated Indicator Transmitter with Anti-interference Design
Input:Temperature
Output:4 ... 20 mA
Display range:-9999 ... 99999
Accuracy:<0.2%
●Additional option:(ILAC/TAF)Test report-Standard calibration laboratory (TAF accreditation:3032, complying with ISO/IEC 17025)
TAF has mutual recognition arrangement with ILAC MRA

eYc TP02 Temperature Transmitter for DIN-rail Type

Product features:Special IC for RTD;high accuracy is assured.High quality and low price.
Input:Pt100(3-wire)
Output:DC 4...20 mA(2-wire)
Accuracy:0.1% of F.S.
Temperature range:-50...+ 50°C / - 50...0°C / 0...50°C / 0...100°C/0...200°C or special range
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA

eYc THS07 Temperature & Humidity Transmitter for Probe Type

Features : Industrial grade class sensor comes with high accuracy and long-term stability.
Input : Capacitive Humidity Sensor & Pt100
Output : Temp. RTD ( Pt100 / NTC10K ) /
Humidity 0 ... 10 V ; 4 ... 20 mA
Accuracy : Temp. ±0.3°C+ 0.002°C x t actual /
Humidity ( at +25°C ) ±3 %RH (30 ... 70 %RH ) of F.S. /
Humidity ( at +15 ... 35°C ) ±5 %RH ( 20 ... 80 %RH ) of F.S.
Measuring Range : 0 ... 50 °C;5 ... 95 %RH
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc THS17 Temperature and Humidity Transmitter (Digital / Analog)

MOQ:100 PCS/YEAR
Feature : Semiconductor MEMS sensor, has nicer long-term stability of measuring and react quickly feature
Output : Digital / Analog / RS-485 ; 4...20mA (2-wire) ; 0...10V(3-wire)
Range : 0 ... 50 °C ; 0 ... 100 %RH(non-cond.)
Accuracy : ± 0.5 °C ; ± 5 %RH
Nice Stability : Non-cond. : Sensor Protected
Housing : SUS304 or PC Fire-proof
●Additional option:( ILAC/TAF ) Test report - Standard calibration laboratory ( TAF accreditation:3032, complying with ISO/IEC 17025 )
TAF has mutual recognition arrangement with ILAC MRA